27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Messages<br />

H<strong>CP</strong>002E Invalid oper<strong>and</strong> - oper<strong>and</strong><br />

H<strong>CP</strong>026E Oper<strong>and</strong> missing or invalid<br />

H<strong>CP</strong>6265A A Monitor writer connected to<br />

iucvserver action<br />

MONWSTOP<br />

is a CMS immediate comm<strong>and</strong>. It causes MONWRITE to stop processing, close<br />

the output file, <strong>and</strong> exit normally.<br />

#<strong>CP</strong> EXTERNAL<br />

is a <strong>CP</strong> comm<strong>and</strong> that causes an external interrupt.<br />

Notes:<br />

1. If the IUCV specified is *MONITOR, <strong>CP</strong> MONITOR, <strong>and</strong> no other users are<br />

connected, data collection goes to a pending state.<br />

2. You should receive the message H<strong>CP</strong>6265A indicating that MONWRITE has<br />

successfully connected to IUCV. If not, use the #<strong>CP</strong> EXTERNAL comm<strong>and</strong> to<br />

stop MONWRITE, because MONWRITE may not be ready to recognize the<br />

MONWSTOP comm<strong>and</strong>. If the MONWSTOP comm<strong>and</strong> is processed when<br />

MONWRITE is not ready to recognize it, it is ignored by MONWRITE. It is<br />

stacked by CMS for future processing—that is, it remains in the program stack<br />

until MONWRITE is successfully stopped by other means. If MONWRITE is not<br />

ready to recognize the #<strong>CP</strong> EXTERNAL comm<strong>and</strong> as well, <strong>CP</strong> passes the<br />

external interrupt to CMS for processing. Refer to “EXTERNAL” on page 433 for<br />

more information.<br />

3. You may use the CMS HX immediate comm<strong>and</strong> to stop MONWRITE, but the<br />

output file is left in an unpredictable state.<br />

H<strong>CP</strong>6266A End-of-tape encountered for vdev,<br />

mount <strong>and</strong> ready a new writable tape<br />

H<strong>CP</strong>6267I Monitor writer connection to iucv<br />

ended<br />

H<strong>CP</strong>6268E Attempt to connect to Monitor Writer<br />

by application has been severed<br />

H<strong>CP</strong>6269E Macro name failed with<br />

{return|condition} code code<br />

H<strong>CP</strong>6270E iucv severed the IUCV connection,<br />

reason code code<br />

H<strong>CP</strong>6271A Warning: output file does not contain<br />

initial sample configuration records<br />

MONWRITE<br />

Chapter 3. <strong>CP</strong> <strong>Utilities</strong> 1855