DEFINE DEVICE / IODEVICE<br />

Authorization<br />

Purpose<br />

Oper<strong>and</strong>s<br />

Privilege Class: B<br />

Use DEFINE DEVICE or IODEVICE to define one or more new real devices to the<br />

I/O configuration.<br />

rdev<br />

rdev1-rdev2<br />

is the real device number (or range of real device numbers) of the device that<br />

you are defining to <strong>CP</strong>. Each rdev must be a 1- to 4-digit hexadecimal number<br />

between X'0000' <strong>and</strong> X'FFFF'.<br />

UNIT_Address nn<br />

UNITADD nn<br />

is the last 2 digits of a device address or number. The variable nn must be a 1-<br />

to 2-digit hexadecimal number between X'00' <strong>and</strong> X'FF'.<br />

Notes:<br />

156 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong><br />

1. If you are specifying a range of devices (rdev1-rdev2), the unit address that<br />

you specify is the starting address associated with the first device in the<br />

range.<br />

TYpe CF<br />

tells <strong>CP</strong> that the specified devices are attached to a control unit that connects to<br />

coupling facility channel paths. Coupling facility channel paths include coupling<br />

facility sender (CFS), coupling facility receiver (CFR), coupling facility peer<br />

(CFP), cluster bus sender (CBS), cluster bus receiver (CBR), cluster bus peer<br />

(CBP), or internal coupling peer (I<strong>CP</strong>) channel paths.<br />

CU_number nnnn<br />

CUNUMBR nnnn<br />

is the number of the control unit associated with the device that you are<br />

defining. You can specify up to 8 control unit numbers. Each nnnn must be a 1-<br />

to 4-digit hexadecimal number between X'0000' <strong>and</strong> X'FFFE'.<br />

CSS nn<br />

is a channel-subsystem ID previously defined for one or more channel paths to<br />

the specified control unit. The variable nn must be a 1- to 2-digit hexadecimal<br />

number between X'00' <strong>and</strong> X'0F'.<br />

Note: This parameter <strong>and</strong> other parameters that identify different<br />

channel-subsystem IDs require that the logical channel-subsystem facility<br />

be installed.<br />

CTCa EXTended<br />

tells <strong>CP</strong> that this device is an extended mode channel-to-channel adapter<br />

(CTCA).<br />

CTCa BASic<br />

tells <strong>CP</strong> that this device is a basic mode channel-to-channel adapter (CTCA).<br />

NOTDASD<br />

tells <strong>CP</strong> that this device is not a direct access storage device (DASD).