TRACE TPI<br />

►►<br />

TRace<br />

Authorization<br />

Purpose<br />

TPI<br />

Oper<strong>and</strong>s<br />

Usage Notes<br />

Responses<br />

range<br />

SIM<br />

NOSIM<br />

Privilege Class: G<br />

options<br />

Use TRACE TPI to trace test pending interruption instructions.<br />

Note: TRACE TPI is accepted if your virtual machine is an ESA or XC virtual<br />

machine; tracing is limited to those instructions that do not produce an<br />

operation or privileged-operation exception.<br />

range<br />

is a range of device numbers. If you specify a device range, only those TPI<br />

instructions that store an interruption is traced. If you do not specify a range, all<br />

TPI instructions are traced. The device range applies to the device name, <strong>and</strong><br />

not the subchannel address.<br />

The range may be a single device number, a device number followed by a<br />

period <strong>and</strong> followed by a number that represents the number of consecutive<br />

device addresses to be traced, or pair of device numbers separated by a period<br />

(.) or a hyphen (-). Wrap-around ranges are not allowed.<br />

NOSIM <strong>and</strong> a device range are not compatible options.<br />

SIM<br />

specifies normal simulation of instructions. If neither SIM nor NOSIM is<br />

specified, SIM is assumed.<br />

NOSIM<br />

specifies suppression of instruction simulation. Program interrupts for guest<br />

PER events are also suppressed. By using NOSIM <strong>and</strong> the CMD option, you<br />

can define a <strong>CP</strong> comm<strong>and</strong> or set of <strong>CP</strong> comm<strong>and</strong>s to be processed in place of<br />

the suppressed instruction. The PSW is left pointing to the next sequential<br />

instruction.<br />

This oper<strong>and</strong> is not valid when TPI specifies a device range.<br />

options<br />

For an explanation of the options, see “TRACE: Options” on page 1604.<br />

1. For usage information, see “Usage Notes” on page 1601.<br />

TRACE TPI<br />

For response information, see “TRACE: Comm<strong>and</strong> Responses” on page 1610.<br />

►◄<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 1657