TERMINAL TIMESTAMP<br />

►►<br />

TERMinal<br />

Authorization<br />

Purpose<br />

Oper<strong>and</strong>s<br />

Usage Notes<br />

TIMEstamp<br />

TIMESTMp<br />

<strong>CP</strong><br />

ON<br />

OFf<br />

Privilege Class: G<br />

Use TERMINAL TIMEstamp/TIMESTMp to control whether messages <strong>and</strong><br />

comm<strong>and</strong> responses on the virtual machine console are prefixed with the local time<br />

of day.<br />

<strong>CP</strong><br />

ON<br />

OFF<br />

If you specify <strong>CP</strong>, control program messages <strong>and</strong> comm<strong>and</strong> responses on the<br />

console are prefixed with the local time of day. ON causes all virtual machine<br />

<strong>and</strong> <strong>CP</strong> messages to be identifed with time stamps. If you specify OFF,<br />

messages are displayed with no prefix.<br />

1. Time stamps are not produced for some <strong>CP</strong> comm<strong>and</strong> responses (for example,<br />

to QUERY READER ALL) to preserve readability.<br />

2. Messages sent to a secondary user for a primary user with TIMESTAMP <strong>CP</strong> are<br />

not prefixed with a time stamp, for compatibility with earlier releases of <strong>VM</strong>. The<br />

time stamp prefix generation that occurs for a secondary user depends on the<br />

TIMESTAMP settings of both the primary <strong>and</strong> secondary users. The sources of<br />

time stamps are summarized in the table below.<br />

Table 23. Time Stamp Prefix Sources<br />

Secondary User<br />

TIMESTAMP<br />

Setting<br />

TERMINAL TIMESTAMP<br />

Primary User TIMESTAMP Setting<br />

<strong>CP</strong> ON OFF<br />

<strong>CP</strong> None Primary user None<br />

ON Secondary user Both users Secondary user<br />

OFF None Primary user None<br />

3. The system default is TIMESTAMP OFF except for the primary system operator<br />

whose TIMESTAMP setting is <strong>CP</strong>.<br />

►◄<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 1599