27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TERMINAL MORE<br />

►►<br />

TERMinal<br />

Authorization<br />

Purpose<br />

Oper<strong>and</strong>s<br />

Usage Notes<br />

Messages<br />

MORE<br />

50 10<br />

mmm<br />

Privilege Class: G<br />

Use TERMINAL MORE to change the number of seconds that elapse between the<br />

time when <strong>CP</strong> issues the MORE... state <strong>and</strong> sounds the terminal alarm <strong>and</strong> between<br />

the time when <strong>CP</strong> sounds the alarm <strong>and</strong> clears the screen.<br />

mmm<br />

tells <strong>CP</strong> the number of seconds that should pass after the MORE... status is<br />

displayed before <strong>CP</strong> sounds the terminal alarm. mmm must be a number<br />

between 0 <strong>and</strong> 255. When you first log on the system, <strong>CP</strong> sets mmm to 50<br />

seconds.<br />

nnn<br />

tells <strong>CP</strong> the number of seconds that should pass after <strong>CP</strong> sounds the terminal<br />

alarm before it clears the screen. nnn must be a number between 0 <strong>and</strong> 255.<br />

When you first log on the system, <strong>CP</strong> sets nnn to 10 seconds.<br />

Initial Setting:<br />

50 10<br />

10<br />

nnn<br />

H<strong>CP</strong>002E Invalid oper<strong>and</strong> - oper<strong>and</strong><br />

H<strong>CP</strong>006E Invalid device type - vdev<br />

1. The TERMINAL MORE comm<strong>and</strong> will give you an error message, H<strong>CP</strong>006E, if<br />

you enter it on a TTY device.<br />

2. If you specify MORE values other than 50 10 on a SNA terminal controlled by a<br />

VTAM Service Machine that does not support the TERMINAL MORE comm<strong>and</strong>,<br />

message H<strong>CP</strong>006E is issued.<br />

3. If you modify the MORE values to something other than the default values of 50<br />

10 <strong>and</strong> reconnect to a SNA terminal controlled by a VTAM Service Machine that<br />

does not support the TERMINAL MORE comm<strong>and</strong>, message H<strong>CP</strong>2555I is<br />

issued to inform you that the MORE values have changed back to 50 10.<br />

4. See “TERMINAL HOLD” on page 1588 for information on how to prevent <strong>CP</strong><br />

from presenting a HOLDING status when the terminal screen fills up <strong>and</strong><br />

highlighted messages appear on the screen.<br />

H<strong>CP</strong>026E Oper<strong>and</strong> missing or invalid<br />

TERMINAL MORE<br />

►◄<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 1593

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!