27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SET SHUTDOWNTIME<br />

►►<br />

Set<br />

Authorization<br />

Purpose<br />

Oper<strong>and</strong>s<br />

Usage Notes<br />

Messages<br />

SHUTDOWNtime<br />

duration<br />

Privilege Class: A, C<br />

H<strong>CP</strong>002E Invalid oper<strong>and</strong> - oper<strong>and</strong><br />

Use SET SHUTDOWNTIME to set the amount of time reserved for a <strong>CP</strong><br />

SHUTDOWN to be performed. When a SHUTDOWN comm<strong>and</strong> is issued or the <strong>VM</strong><br />

system shuts down automatically as the result of receiving a hardware deactivation<br />

signal, there is a time interval within which the shutdown must be completed. The<br />

SHUTDOWNTIME duration specifies how much of the time interval is reserved for<br />

<strong>CP</strong>, <strong>and</strong> the difference between the time interval <strong>and</strong> the time reserved for <strong>CP</strong><br />

determines how much time, if any, guests are allowed to use to perform their own<br />

shutdown processing.<br />

duration<br />

is the amount of time reserved for <strong>CP</strong> shutdown processing, in seconds. It must<br />

be a value between 0 <strong>and</strong> 32767.<br />

1. This comm<strong>and</strong> takes effect only when the WITHIN interval or BY hh:mm:ss<br />

options of the SHUTDOWN comm<strong>and</strong> are used. If these options are not<br />

specified on the comm<strong>and</strong>, the SHUTDOWNTIME <strong>and</strong> SIGNAL SHUTDOWN<br />

times are added together <strong>and</strong> that is the time allowed for the shutdown, if<br />

necessary. Refer to “SHUTDOWN” on page 1433.<br />

2. When a <strong>CP</strong> shutdown occurs due to a hardware deactivation, <strong>and</strong> if the<br />

SHUTDOWNTIME is more than 300 seconds (5 minutes), there will not be time<br />

left for guests to shut down.<br />

H<strong>CP</strong>003E Invalid option - comm<strong>and</strong> contains<br />

extra option(s) starting with option}<br />

H<strong>CP</strong>6704E Missing token at end of line<br />

H<strong>CP</strong>6706E Invalid string - string<br />

H<strong>CP</strong>6706E Invalid time - time<br />

SET SHUTDOWNTIME<br />

►◄<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 1387