SET SCMEASURE<br />

Responses<br />

device should be disabled for collecting subchannel measurements when it is<br />

initialized, <strong>CP</strong> does not prevent you from turning subchannel measuring on for<br />

that device after it is initialized.<br />

5. The SET SCMEASURE comm<strong>and</strong> will assign an SCMBK to a device or return<br />

an assigned SCMBK to the available pool to be reused. To obtain information<br />

on the number of SCMBKs on your system, use the QUERY SCMBKS<br />

comm<strong>and</strong> (page 982).<br />

Format-0 measurement blocks:<br />

1. During initialization, <strong>CP</strong> allocates 1 SCMBK for every subchannel on the system<br />

<strong>and</strong> rounds the amount of storage up to the nearest page boundary. Thus, you<br />

have enough SCMBK space for every real device on your system plus some<br />

free SCMBK space. How much free SCMBK space you have will vary,<br />

depending upon how many real devices you have on your system.<br />

2. You should plan for additional SCMBK space if you intend to dynamically add<br />

new real devices to your running system. At initialization, you can allocate more<br />

free SCMBK space than <strong>CP</strong> would normally allocate using the SCMBK oper<strong>and</strong><br />

of the STORAGE statement in the system configuration file. For more<br />

information, see the z/<strong>VM</strong>: <strong>CP</strong> Planning <strong>and</strong> Administration book.<br />

3. If you run out of free SCMBK space on a running system <strong>and</strong> you need to<br />

measure additional real devices, you have two choices:<br />

a. Re-IPL <strong>and</strong> specify more free SCMBK space using the SCMBK oper<strong>and</strong><br />

mentioned in Usage Note 2, or<br />

b. Stop collecting subchannel measurement data for one or more devices.<br />

When you use one of the following comm<strong>and</strong>s:<br />

v DELETE DEVICE (page 223)<br />

v DELETE IODEVICE (page 223)<br />

v DELETE RDEVICE (page 228)<br />

v SET SCMEASURE OFF (page 1377)<br />

<strong>CP</strong> returns the SCMBK assigned to that device (or devices) to the pool of<br />

available SCMBKs. It is then available to be used to collect subchannel<br />

measurement data for another device.<br />

Response 1:<br />

To tell <strong>CP</strong> to begin collecting subchannel measurement data for devices 127<br />

through 130, enter the following SET SCMEASURE comm<strong>and</strong>:<br />

set scmeasure on 127-130<br />

Subchannel measuring for device 0127 is on<br />

Subchannel measuring for device 0128 is on<br />

Subchannel measuring for device 0129 is already on<br />

Subchannel measuring for device 012A is already on<br />

Subchannel measuring for device 012B is on<br />

Subchannel measuring for device 012C is on<br />

Subchannel measuring for device 012D is on<br />

Subchannel measuring for device 012E is already on<br />

Subchannel measuring for device 012F is already on<br />

Subchannel measuring for device 0130 is on<br />

Ready;<br />

Note that <strong>CP</strong> was already collecting subchannel measurement data for devices 129,<br />

12A, 12E, <strong>and</strong> 12F.<br />

Response 2:<br />

1378 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong>