SET NVS<br />

Messages<br />

Response 2:<br />

Immediate Response: If you enter the SET NVS OFF comm<strong>and</strong> <strong>and</strong> the NVS is<br />

made unavailable to the subsystem immediately, the following response is<br />

displayed. This response is repeated for each unique subsystem identified by the<br />

devices specified on the comm<strong>and</strong><br />

rdev Nonvolatile storage has been deactivated.<br />

rdev<br />

is the real device number of one of the specified devices in a subsystem for<br />

which the NVS has been deactivated.<br />

Delayed Response: If the NVS is not made unavailable to the subsystem<br />

immediately, the following response is displayed:<br />

Comm<strong>and</strong> started: SET NVS OFF rdev.<br />

When the NVS is made unavailable to the subsystem, the following responses are<br />

displayed:<br />

rdev Nonvolatile storage has been deactivated.<br />

Under certain circumstances, it is possible that a cache storage subsystem does<br />

not notify <strong>CP</strong> when it has made the NVS unavailable to the subsystem. When this<br />

occurs, the appropriate comm<strong>and</strong> response cannot be generated. Under these<br />

circumstances, comm<strong>and</strong> processing is ended after generating the following<br />

response:<br />

Comm<strong>and</strong> results lost: SET NVS OFF rdev.<br />

In this case, the QUERY NVS comm<strong>and</strong> can be issued to determine the state of the<br />

nonvolatile storage.<br />

If errors occur during the asynchronous processing of the comm<strong>and</strong> that prevent<br />

the successful completion of the comm<strong>and</strong>, the following response is displayed:<br />

Comm<strong>and</strong> failed: SET NVS OFF rdev.<br />

rdev<br />

is the real device number of one of the specified devices in a subsystem for<br />

which the comm<strong>and</strong> has failed.<br />

Response to System Operator: If the originator of the comm<strong>and</strong> is not the system<br />

operator, the following response is issued to the system operator when the NVS<br />

has been made unavailable to the subsystem. This response is also repeated for<br />

each unique subsystem identified by the devices specified on the comm<strong>and</strong> line.<br />

rdev Nonvolatile storage was deactivated by userid.<br />

rdev<br />

is the real device number of one of the specified devices in a subsystem for<br />

which the NVS has been deactivated.<br />

userid<br />

is the ID of the user who issued the comm<strong>and</strong>.<br />

H<strong>CP</strong>006E Invalid device type - {rdev|vdev|ldev}<br />

H<strong>CP</strong>009E Invalid range - range<br />

1306 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong><br />

H<strong>CP</strong>021E A real device number was not supplied<br />

or it is invalid.<br />

H<strong>CP</strong>026E Oper<strong>and</strong> missing or invalid