SET LKFACR<br />

►►<br />

Set<br />

Authorization<br />

Purpose<br />

LKFACR<br />

Oper<strong>and</strong>s<br />

Usage Notes<br />

Responses<br />

ON<br />

OFF<br />

▼<br />

Privilege Class: G<br />

Use SET LKFACR to control whether a full-pack minidisk is to use the real<br />

multi-path lock facility (MPLF) of a 3990 model 6 control unit.<br />

ON<br />

indicates that the device will use the real MPLF facility<br />

OFF<br />

indicates that the device will not use the real MPLF facility.<br />

vdev<br />

vdev1-vdev2<br />

is the virtual device number or range of virtual device numbers of the devices to<br />

be enabled or disabled for real MPLF.<br />

1. Attention: SET LKFACR ON causes a SYSTEM RESET of your virtual<br />

machine whenever one or more of the specified virtual devices have been<br />

enabled for MPLF simulation through the SET LKFAC comm<strong>and</strong>. Use the<br />

QUERY LKFAC comm<strong>and</strong> just before issuing SET LKFACR ON to see a current<br />

list of the virtual devices that would cause such a SYSTEM RESET of your<br />

virtual machine.<br />

2. SET LKFACR ON will prevent the virtual device from using simulated MPLF<br />

until the next SYSTEM RESET.<br />

3. The virtual machine must have lock facility authorization in order to use the real<br />

MPLF facility. See directory OPTION LKFAC in the z/<strong>VM</strong>: <strong>CP</strong> Planning <strong>and</strong><br />

Administration.<br />

4. SET LKFACR ON is only valid for full-pack minidisks. Non-full-pack minidisks<br />

can only use the simulated MPLF facility. For more information, see “SET<br />

LKFAC” on page 1271. Dedicated DASD always use the real MPLF facility,<br />

provided that the virtual machine has the proper authorization. See directory<br />

OPTION LKFAC in the z/<strong>VM</strong>: <strong>CP</strong> Planning <strong>and</strong> Administration.<br />

Response 1:<br />

vdev<br />

vdev1-vdev2<br />

Real MPLF is {enabled } for DASD vdev<br />

{disabled}<br />

is issued when the comm<strong>and</strong> completes successfully.<br />

SET LKFACR<br />

►◄<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 1273