If query information is not available for at least one device in a range, then a<br />

generic error message will be issued. For example:<br />

query scmeasure 100-102<br />

H<strong>CP</strong>CHC1003E 0100-0102 was not found<br />

Ready(01003);<br />

Response 1:<br />

To find out whether <strong>CP</strong> is collecting subchannel measurement data for device 131,<br />

enter the following QUERY SCMEASURE comm<strong>and</strong>:<br />

query scmeasure 131<br />

Subchannel measuring for device 0131 is on<br />

Ready;<br />

Response 2:<br />

H<strong>CP</strong>003E Invalid option - option<br />

To find out which devices <strong>CP</strong> is collecting subchannel measurement data for in the<br />

device range 750 through 759, enter the following QUERY SCMEASURE<br />

comm<strong>and</strong>:<br />

query scmeasure 750-759<br />

Subchannel measuring for device 0750 is off<br />

Subchannel measuring for device 0751 is off<br />

Subchannel measuring for device 0752 is on<br />

Subchannel measuring for device 0753 is on<br />

Subchannel measuring for device 0754 is on<br />

Subchannel measuring for device 0755 is off<br />

Subchannel measuring for device 0756 is on<br />

Subchannel measuring for device 0757 is on<br />

Ready;<br />

This example shows that:<br />

H<strong>CP</strong>009E Invalid range - rdev-rdev<br />

v <strong>CP</strong> is not collecting subchannel measurement data for devices 750, 751, <strong>and</strong> 755<br />

v <strong>CP</strong> is collecting subchannel measurement data for devices 752, 753, 754, 756,<br />

<strong>and</strong> 757<br />

H<strong>CP</strong>021E A real device number was not supplied<br />

or it is invalid.<br />

H<strong>CP</strong>040E Device rdev does not exist<br />

H<strong>CP</strong>1003E rdev was not found.<br />

H<strong>CP</strong>6706E Invalid RDEV - rdev. RDEV not<br />

initialized<br />

QUERY SCMEASURE<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 985