88 Part II: Metrology

on certain parts or assemblies. If a part or an assembly is close to being

out of specification, the estimated uncertainty may be the deciding

factor in the acceptance/rejection decision.

Part II.C.3

• Calibration and/or test data. Prior to submitting a device or object for

testing or calibration, a list of the measurements that will be taken and

a sample data report should be known.

• Ensuring quality of calibration and testing results. ANSI/ISO/IEC 17025-

2005 lists many methods that labs can use to ensure the quality of

their calibration and testing results. One of these, proficiency testing,

has since become a requirement by many accreditation bodies.

• Produce measurements that are traceable to some national or