03.05.2023 Views

vdoc

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Factory

air line

Regulator

Filter

Adjustable

restrictor

1

(a)

Workpiece

(e)

Atmospheric bleed for

indicator zeroing

Indicator

Bourdon tube

Fixed

restrictor

Gage head

Figure 8.3 Diagram of air gage principles.

Indicator

Indicator

Mechanical

amplifying device

Bellows

Factory

air line

Filter

Fixed restrictor

To gage head

Mechanical amplifying device

Regulator

2

3

1

Factory

air line

Regulator

Developed

glass tube

Factory

air line

Regulator

(b) (c) (d)

3

1

2

3 1

(f) (g) (h) (i)

Indicator

Bellows

Large venturi

chamber

To gage head

Reprinted with permission of the Society of Manufacturing Engineers, Manufacturing Processes and Materials, 4th edition, copyright 2000.

Filter

Filter

1

2 2

3

Airflow

lines

3

Mechanical

amplifying

device

Small

venturi

chamber

Indicator

adjusting

knob

Chapter 8: B. Special Gages and Applications 81

Part II.B.3