Installation, Maintenance and Operation Manual - Tyco Thermal ...
Installation, Maintenance and Operation Manual - Tyco Thermal ... Installation, Maintenance and Operation Manual - Tyco Thermal ...
cable to electrical heat tracing systems, as well as the requirements of other International Standards, such as IEC 62086. Personal involved in the installation, testing and maintenance of electric heat tracing systems must be suitably trained in all special techniques required, as well as in general electrical installation work. All work should be monitored by supervisors, experienced in heat tracing applications, and all installations must be carried out using the appropriate tools as described in the Tyco Thermal Controls literature and installation instructions. Area Classification – Ordinary XPI-NH Area Classification - Hazardous, Zone 1 or Zone 2 Special conditions for safe use in hazardous area: Please refer to relevant Hazardous area certifications Certificate No. Approvals coding XPI (system) PTB 03 ATEX 1218 X II 2 G/D EEx e II T6-T2 XPI (bulk cable) PTB 05 ATEX 1060 U II G/D EEX e II Tp 260°C XPI-S (system) PTB 03 ATEX 1218 X II 2 G/D EEx e II T6-T2 XPI-S (bulk cable) PTB 05 ATEX 1060U II 2 G/D EEx e II Tp 260°C Other national approvals: Please contact Tyco Thermal Controls 5
- Page 1 and 2: Installation, Maintenance and Opera
- Page 4: 1 General information Use of the ma
- Page 10: 3 of the heating cable defined by t
- Page 14: 9 d excessive pulling force d kinki
- Page 18: 3.5 Attachment tapes GT-66 Glass cl
- Page 22: Figure 11-12: Cable applied on wire
- Page 26: 4 For some applications, it may be
- Page 30: D In cases where stabilised design
- Page 34: 6.2 Insulation related requirements
- Page 38: 8 System testing WARNING: Fire haza
- Page 42: 9.3 Piping systems repair and maint
- Page 46: 27 28 29 TRIPHASED INSTALLATION REC
- Page 50: C Symptom: No power output. Probabl
cable to electrical heat tracing systems, as well as the<br />
requirements of other International St<strong>and</strong>ards, such as<br />
IEC 62086.<br />
Personal involved in the installation, testing <strong>and</strong> maintenance<br />
of electric heat tracing systems must be suitably<br />
trained in all special techniques required, as well as in<br />
general electrical installation work. All work should be<br />
monitored by supervisors, experienced in heat tracing applications,<br />
<strong>and</strong> all installations must be carried out using the<br />
appropriate tools as described in the <strong>Tyco</strong> <strong>Thermal</strong> Controls<br />
literature <strong>and</strong> installation instructions.<br />
Area Classification – Ordinary<br />
XPI-NH<br />
Area Classification - Hazardous,<br />
Zone 1 or Zone 2<br />
Special conditions for safe use in hazardous area:<br />
Please refer to relevant Hazardous area certifications<br />
Certificate No. Approvals coding<br />
XPI (system)<br />
PTB 03 ATEX 1218 X II 2 G/D EEx e II T6-T2<br />
XPI (bulk cable)<br />
PTB 05 ATEX 1060 U II G/D EEX e II Tp 260°C<br />
XPI-S (system)<br />
PTB 03 ATEX 1218 X II 2 G/D EEx e II T6-T2<br />
XPI-S (bulk cable)<br />
PTB 05 ATEX 1060U II 2 G/D EEx e II Tp 260°C<br />
Other national approvals:<br />
Please contact <strong>Tyco</strong> <strong>Thermal</strong> Controls<br />
5