9.3 Piping systems repair <strong>and</strong> maintenance<br />
10<br />
D Isolate heating cable circuit <strong>and</strong> protect the heating cable<br />
from mechanical or thermal damage during pipe repair<br />
work.<br />
D Check heating cable installation after pipe repairs <strong>and</strong><br />
make sure that thermal insulation is restored according to<br />
the recommendations in Section 6. Check correct functioning<br />
of all relevant electrical protection systems.<br />
Trouble Shooting<br />
WARNING: Damage to cables or components can<br />
cause sustained electrical arcing or fire. Do not energize<br />
heating cables that have been damaged. Damaged<br />
heating cable, splices or connections must be repaired or<br />
replaced. Damaged cable should be repaired by a qualified<br />
person.<br />
D It should be carefully evaluated, whether the severity of the<br />
damage allows on-site repair or whether the entire<br />
heating cable needs to be replaced.<br />
Also refer to the Troubleshooting guide on the following<br />
pages. If the problem persists after following the guidelines,<br />
contact <strong>Tyco</strong> <strong>Thermal</strong> Controls.<br />
23