Viessmann refrigeration and deep-freeze units
Viessmann refrigeration and deep-freeze units
Viessmann refrigeration and deep-freeze units
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Viessmann</strong> <strong>refrigeration</strong><br />
<strong>and</strong> <strong>deep</strong>-<strong>freeze</strong> <strong>units</strong><br />
Wall-hanging <strong>units</strong> with electronic control (front),<br />
finished in stainless steel with thermostatic control (rear)<br />
Use the full refrigerating capacity <strong>and</strong> save energy!<br />
Our company’s production of <strong>refrigeration</strong><br />
<strong>units</strong> enables us to offer an ideal<br />
system complement to the coldrooms<br />
made by nearly every manufacturer.<br />
The functions of <strong>Viessmann</strong> <strong>refrigeration</strong><br />
<strong>units</strong> are specially tailored to customers’<br />
needs <strong>and</strong> can be installed without<br />
spending a great deal of time or<br />
energy. No matter whether you are<br />
considering wall-hanging, split- or<br />
ceiling-mounted <strong>units</strong> with electronic<br />
or thermostatic control, <strong>Viessmann</strong><br />
<strong>refrigeration</strong> <strong>units</strong> impress not only<br />
with their ready to plug in commissioning<br />
but also with their above average<br />
cooling capacity based on the use of<br />
high quality components <strong>and</strong> well<br />
thought-out <strong>refrigeration</strong> cycles. This<br />
capacity makes for longer life <strong>and</strong> lower<br />
power consumption. The <strong>refrigeration</strong><br />
cycle of <strong>Viessmann</strong> <strong>refrigeration</strong> <strong>units</strong> is<br />
soldered throughout to guarantee a<br />
high level of operational safety. All<br />
parts are easy to access, permanently<br />
lowering maintenance <strong>and</strong> repair costs.<br />
This is an economical <strong>and</strong> indispensable<br />
product advantage adding to<br />
<strong>Viessmann</strong> <strong>refrigeration</strong> <strong>units</strong>’ lownoise<br />
design <strong>and</strong> long life.<br />
Cooling capacity<br />
from 500 to 2765 W<br />
Electronic or<br />
thermostatic control<br />
A wide range of<br />
operational ambient<br />
temperatures from<br />
+2°C to +43°C<br />
Low energy consumption<br />
Long life<br />
Ready to plug in<br />
commissioning<br />
Air <strong>and</strong> water cooled<br />
version<br />
Wall-hanging<br />
installation<br />
Ceiling-mounted <strong>refrigeration</strong> unit
2<br />
Wall-hanging, split <strong>and</strong> ceiling-mounted <strong>units</strong> for every situation<br />
Heat exchanger unit<br />
<strong>Viessmann</strong> wall-hanging<br />
<strong>refrigeration</strong> <strong>units</strong><br />
The ready to plug in <strong>Viessmann</strong> wallhanging<br />
<strong>units</strong> are inserted into a coldroom<br />
or a wall between 60 <strong>and</strong> 150 mm<br />
thick with optional electronic or thermostatic<br />
control. The cooling capacity<br />
for coldrooms ranges from 500 to 2765<br />
W in air-cooled or water-cooled versions.<br />
Alternatively electric defrosting or<br />
circulating air defrosting in the temperature<br />
area over +3°C is available. R 134<br />
a refrigerant is used (R 404 A in the case<br />
of chiller <strong>units</strong>). Production is according<br />
to EN-st<strong>and</strong>ards, in agreement with CE.<br />
Wall-hanging <strong>refrigeration</strong> unit (water-cooled) with<br />
electronic control<br />
<strong>Viessmann</strong> split<br />
<strong>refrigeration</strong> <strong>units</strong><br />
<strong>Viessmann</strong> split <strong>refrigeration</strong> <strong>units</strong> are<br />
suitable for installation in a coldroom or<br />
a conventional <strong>refrigeration</strong> room. Warm<br />
<strong>and</strong> cold sections can be assembled up<br />
to 15 m in distance from one another.<br />
These are available with electronic control.<br />
The cooling capacity for coldrooms<br />
ranges from 900 to 2765 W in air-cooled<br />
or water-cooled design. Alternatively<br />
electric defrosting or circulating air<br />
defrosting in the temperature area over<br />
+3°C is available. R 134 a refrigerant is<br />
used (R 404 A in the case of chiller<br />
<strong>units</strong>). Production is according to ENst<strong>and</strong>ards,<br />
in agreement with CE.<br />
Panel of the electronic control SE<br />
Wall-hanging unit (evaporator) installation<br />
<strong>Viessmann</strong> ceiling-mounted<br />
<strong>refrigeration</strong> <strong>units</strong><br />
Easy to assemble on the coldroom ceiling<br />
as the lower edge of the unit is planar<br />
<strong>and</strong> facilitates its positioning on the<br />
roof. The unit does not take up more<br />
space than the coldroom takes up on<br />
the ground. It is available with electronic<br />
control. Several <strong>units</strong> in a coldroom<br />
can be operated in a network using a<br />
bus connection. The cooling capacity<br />
for coldrooms ranges from 800 to 2600<br />
W in air-cooled or water-cooled design<br />
with condensate evaporation. The refrigerant<br />
is R 404 A <strong>and</strong> the unit is produced<br />
according to EN-st<strong>and</strong>ards, in agreement<br />
with CE.<br />
Split <strong>refrigeration</strong> unit Ceiling-mounted <strong>refrigeration</strong> unit
Fittings <strong>and</strong> functional features which do the job!<br />
High quality German production<br />
with reliable spare parts supply<br />
Full cooling performance with<br />
increased effectiveness as a result<br />
of use of an additional reverse<br />
current heat exchanger <strong>and</strong><br />
thermostatically controlled<br />
expansion valves<br />
All models are also available in<br />
water-cooled versions. Please<br />
consult us for further information<br />
Fully automatic electrical defrosting<br />
depending on requirements or optional<br />
air circulation defrosting for<br />
coldroom temperatures above +3°C<br />
Special solutions for controlled<br />
atmosphere through connection of<br />
the <strong>units</strong> with E-heating <strong>and</strong>/or<br />
humidification<br />
Pleasantly quiet <strong>and</strong> noise<br />
protection-tested operation<br />
Low power consumption<br />
High level of operating safety due<br />
to soldering in the <strong>refrigeration</strong><br />
cycle equipment<br />
Uncomplicated commissioning with<br />
the ready to plug in assembled<br />
system<br />
Modular construction, easy to<br />
assemble <strong>and</strong> maintain<br />
Connectors for a door contact<br />
switch<br />
Humidity control for higher or lower<br />
relative air humidity in the<br />
coldroom<br />
Strong housing made of galvanized<br />
steel sheeting with robust powder<br />
Functions of the electronic controls SE <strong>and</strong> SD<br />
(among others)<br />
Adjustable parameters of display<br />
<strong>and</strong> layout:<br />
• Desired temperature*<br />
• Defrost cycle (hrs)*<br />
• Defrost time (mins)*<br />
• Language (SD only)<br />
• Display of evaporator<br />
temperature (SD)<br />
• Display of condenser<br />
temperature (SD)<br />
* Password protection if required or this<br />
may be adjusted by yourself (SD)<br />
Three adjustable defrost modes:<br />
• According to prescribed cycle times<br />
• According to cycle times depending<br />
on the compressor running time (SD)<br />
• Start using door contact switch (SD)<br />
Ceiling-mounted <strong>refrigeration</strong> unit, open Wall-hanging <strong>refrigeration</strong> unit, open<br />
Upper <strong>and</strong> lower alarm<br />
temperature can be defined (SD)<br />
Minimum RPM speed for<br />
condenser fan adjustable in<br />
percent (SD)<br />
Fault displays:<br />
• Short circuit in the room sensors<br />
• Break down of the room sensors<br />
• Pressostat malfunction<br />
• Operating temperature too high<br />
• Operating temperature too low<br />
• Coldroom door open<br />
• Evaporator-fan sensor defect (SD)<br />
• Condenser sensor defect (SD)<br />
• Emergency run switch ON (SD)<br />
• EEPROM defect (SD)<br />
coating (white, similar to RAL 9016).<br />
The <strong>units</strong> are available in stainless<br />
steel or effective antimicrobial<br />
SilverProtec® coating, on request.<br />
Electronic or thermostatic control<br />
230 V/60 Hz-variations for ship<br />
supply systems <strong>and</strong> other foreign<br />
networks available on request<br />
Functional tests possible with the<br />
motor running <strong>and</strong> the housing<br />
open<br />
Wall-hanging <strong>refrigeration</strong> unit (water-cooled), open<br />
Water-cooled unit connections<br />
3
4<br />
Refrigeration unit specifications: Wall-hanging <strong>refrigeration</strong> <strong>units</strong> Split <strong>refrigeration</strong> <strong>units</strong> Ceiling-mounted <strong>refrigeration</strong> <strong>units</strong><br />
Cooling application<br />
Coldroom temperature (°C)<br />
Admissible ambient temperature (°C)<br />
Refrigerant<br />
Control<br />
1) Cooling water temperature 6°C to 26 °C, differential pressure of cooling water min. 0.8 bar<br />
2) Compressor with oil heating<br />
<strong>Viessmann</strong> Kältetechnik AG<br />
Schleizer Straße 100<br />
95030 Hof/Saale - Germany<br />
Phone +49 (0) 92 81/8 14-0<br />
Fax +49 (0) 92 81/8 14-2 69<br />
info@vkag.de<br />
www.vkag.de<br />
Normal <strong>refrigeration</strong><br />
-2 to +19<br />
+1 to +43<br />
R134a<br />
Thermostatic<br />
or electronic<br />
Deep <strong>freeze</strong><br />
-1 to -25<br />
+1 to +32<br />
R 404 A<br />
Thermostatic<br />
or electronic<br />
Normal <strong>refrigeration</strong><br />
-2 to +19<br />
+1 to +43<br />
R134a<br />
Electronic<br />
Deep <strong>freeze</strong><br />
-1 to -25<br />
+1 to +32<br />
R 404 R<br />
Electronic<br />
Normal <strong>refrigeration</strong><br />
-5 to +20<br />
+2 to +40<br />
R 404 A<br />
Electronic<br />
Quality<br />
made in Germany<br />
Quality made in<br />
Germany<br />
Deep <strong>freeze</strong><br />
-5 to -25<br />
+2 to +40<br />
R 404 R<br />
Electronic<br />
Cooling medium Air Water 1 Air Water 1 Air Water 1 Air Water 1 Air Water 1 Air Water 1<br />
Types<br />
Cooling capacity (W)<br />
at coldroom temperature +5°C<br />
(CS <strong>and</strong> CT) or -18°C (FS <strong>and</strong> FT) <strong>and</strong><br />
ambient temperature of +32°C<br />
Extracted air flow rate minimal (m 3 /h)<br />
at an ambient temperature of +32°C <strong>and</strong><br />
being warmed up by +5°C<br />
Cooling water consumption ca. (l/h) -<br />
Max. water capacity (l/h) -<br />
Cooling water connection<br />
i. = inside<br />
a. = outside<br />
Voltage (V)/phases/frequency (Hz)<br />
Nominal consumption (W)/<br />
fuse protection (A)<br />
Level of sound pressure (dB (A))<br />
measured at 1 m distance <strong>and</strong> 1.6 m<br />
height at the nominal capacity<br />
Weight (kg)<br />
Dimensions (in mm)<br />
height x width x depth<br />
of split <strong>refrigeration</strong> <strong>units</strong>:<br />
only condenser unit (warm part)<br />
CS 0500<br />
CS 0900<br />
CS 1300<br />
CS 2000<br />
CS 28002 500<br />
925<br />
1300<br />
2050<br />
2765<br />
550<br />
800<br />
1300 -<br />
1700<br />
3250<br />
30<br />
50<br />
72<br />
92<br />
130<br />
80<br />
90<br />
310<br />
310<br />
480<br />
1/2” i.<br />
1/2” i.<br />
- 1/2” i.<br />
1/2” i.<br />
1/2” i.<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
240/10<br />
530/10<br />
720/10<br />
1100/10<br />
1580/10<br />
39<br />
40<br />
41<br />
39<br />
40<br />
49,5<br />
52,7<br />
60,0<br />
89,7<br />
101,0<br />
200/10<br />
490/10<br />
680/10<br />
1035/10<br />
1515/10<br />
37<br />
38<br />
39<br />
37<br />
38<br />
47,5<br />
50,7<br />
58,0<br />
87,7<br />
99,0<br />
700x427x880<br />
700x427x880<br />
700x427x880<br />
850x600x1059<br />
850x600x1059<br />
FS 0900<br />
FS 1200<br />
FS 1400<br />
FS 18002 FS 24002 900<br />
1210<br />
1330<br />
1820<br />
2450<br />
1050<br />
1350<br />
1650 -<br />
1950<br />
2550<br />
50<br />
70<br />
- 105<br />
105<br />
135<br />
160<br />
350<br />
- 510<br />
510<br />
620<br />
1/2” i.<br />
1/2” i.<br />
- 1/2” i.<br />
1/2” i.<br />
1/2” i.<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
400/3/50<br />
400/3/50<br />
750/10<br />
930/10<br />
1440/10<br />
1690/16<br />
2270/16<br />
41<br />
42<br />
42<br />
42<br />
45<br />
62,0<br />
68,0<br />
98,0<br />
101,0<br />
104,0<br />
710/10<br />
890/10<br />
1375/10<br />
1625/10<br />
2205/10<br />
39<br />
40<br />
40<br />
40<br />
43<br />
60,0<br />
66,0<br />
96,0<br />
99,0<br />
102,0<br />
700x427x880<br />
700x427x880<br />
850x600x1059<br />
850x600x1059<br />
850x600x1059<br />
CS 0900 Split<br />
CS 1300 Split<br />
CS 2000 Split<br />
CS 2800 Split 2<br />
800<br />
1300<br />
1700<br />
3250<br />
-<br />
-<br />
-<br />
925<br />
1300<br />
2050<br />
2765<br />
-<br />
50<br />
72<br />
92<br />
130<br />
90<br />
310<br />
310<br />
480<br />
1/2” i.<br />
1/2” i.<br />
1/2” i.<br />
1/2” i.<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
530/10<br />
720/10<br />
1100/10<br />
1580/10<br />
40<br />
41<br />
39<br />
40<br />
52,7<br />
60,0<br />
89,7<br />
101,0<br />
490/10<br />
680/10<br />
1035/10<br />
1515/10<br />
38<br />
39<br />
37<br />
38<br />
50,7<br />
58,0<br />
87,7<br />
99,0<br />
700x427x320<br />
700x427x320<br />
850x600x420<br />
850x600x420<br />
FS 0900 Split<br />
FS 1200 Split<br />
FS 1400 Split<br />
FS 1800 Split2 FS 2400 Split2 900<br />
1210<br />
1330<br />
1820<br />
2450<br />
1050<br />
1350<br />
1650 -<br />
1950<br />
2550<br />
50<br />
70<br />
- 105<br />
105<br />
135<br />
160<br />
350<br />
- 510<br />
510<br />
620<br />
1/2” i.<br />
1/2” i.<br />
- 1/2” i.<br />
1/2” i.<br />
1/2” i.<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
400/3/50<br />
400/3/50<br />
750/10<br />
930/10<br />
1440/10<br />
1690/16<br />
2270/16<br />
41<br />
42<br />
42<br />
42<br />
45<br />
52,7<br />
60,0<br />
93,0<br />
89,7<br />
101,0<br />
710/10<br />
890/10<br />
1375/10<br />
1625/10<br />
2205/10<br />
39<br />
40<br />
40<br />
40<br />
43<br />
50,7<br />
58,0<br />
91,0<br />
87,7<br />
99,0<br />
700x427x320<br />
700x427x320<br />
850x600x420<br />
850x600x420<br />
850x600x420<br />
CT 0900<br />
CT 1200<br />
CT 1500<br />
CT 2000<br />
CT 30002 950<br />
1150<br />
1450<br />
1800<br />
2600<br />
950<br />
1150<br />
1650 -<br />
2050<br />
3350<br />
50<br />
72<br />
- 82<br />
92<br />
130<br />
90<br />
310<br />
- 310<br />
310<br />
480<br />
1/2” a.<br />
1/2” a.<br />
- 1/2” a.<br />
3/4” a.<br />
3/4” a.<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
650/16<br />
840/16<br />
930/16<br />
1400/16<br />
2000/16<br />
40<br />
41<br />
42<br />
43<br />
46<br />
62,5<br />
67,0<br />
67,5<br />
97,5<br />
110,0<br />
610/16<br />
800/16<br />
890/16<br />
1260/16<br />
1860/16<br />
38<br />
39<br />
40<br />
41<br />
44<br />
60,5<br />
65,0<br />
65,5<br />
95,5<br />
108,0<br />
370x650x890<br />
370x650x890<br />
370x650x890<br />
470x827x980<br />
470x827x980<br />
850<br />
1050<br />
1400<br />
1950<br />
-<br />
-<br />
-<br />
FT 1000<br />
FT 1200<br />
FT 1500<br />
800<br />
1100<br />
1400<br />
-<br />
70<br />
105<br />
135<br />
350<br />
510<br />
620<br />
3/4” a.<br />
3/4” a.<br />
3/4” a.<br />
230/1/50<br />
230/1/50<br />
230/1/50<br />
1030/16<br />
1300/16<br />
1990/16<br />
43<br />
43<br />
44<br />
96,0<br />
97,0<br />
114,5<br />
890/16<br />
1260/16<br />
1860/16<br />
41<br />
41<br />
42<br />
94,0<br />
95,0<br />
112,5<br />
470x827x980<br />
470x827x980<br />
470x827x980<br />