4. Overall Level Characteristic and Distortion Factor<br />

Check<br />

Purpose:<br />

Check the record level, play level, and distortion factor against the<br />

reference input.<br />

Mode REC and PB (SP mode)<br />

Signal 400 Hz, –6.3 dBs<br />

Measurement point Audio output terminal<br />

Measurement equipment Audio level meter and<br />

distortion factor meter<br />

Specified value Playback level: –6.3 ± 3 dBs<br />

Distortion factor: 4% or less<br />

Confirmation Method:<br />

1) Supply an audio signal of 400 Hz, –6.3 dBs simultaneously to<br />

both L and R channels of Audio Line Input.<br />

2) Make recording<br />

3) Play back a recorded portion.<br />

4) Confirm that a playback level is –6.3 ± 3 dBs.<br />

5) Confirm that a distortion factor is within 4%.<br />

5. Overall S/N Check<br />

Purpose:<br />

Confirm that the S/N is within the specification.<br />

Mode REC and PB (SP mode)<br />

Signal No signal<br />

Measurement point Audio output terminal<br />

Measurement equipment Audio level meter<br />

Specified value –45.5 dBs or less<br />

Confirmation Method:<br />

1) Connect both L and R channels of audio line input to the GND.<br />

2) Start recording.<br />

3) Play the recorded part to confirm that the noise is below –45.5<br />

dBs.<br />

7-7