5 35<br />

19 23<br />

1500 lm tc 2500 lm<br />

Ø3.2<br />

50 50<br />

50<br />

tc<br />

Technical Design-in Guide<br />

tc<br />

50<br />

20,15 20,15 20,15<br />

6.5<br />

1500 lm tc 2500 lm<br />

Tengine <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

Ø3.2<br />

19


&nbsp Table of Contents<br />

Table of contents<br />

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />

Complete system solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />

Creative freedom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />

Perfect white light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />

Excellent economy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />

Summary of the chapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />

System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />

Mechanical aspects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />

Electrical aspects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />

Optical aspects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />

Thermal aspects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />

Ordering information and sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />

System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />

One system - three versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />

Type codes and versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

Standards and directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

Mechanical aspects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29<br />

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29<br />

Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

Electrical aspects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

Connections on the converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39<br />

Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

Optical aspects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

Colour spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

Coordinates and tolerances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

Reflector design and beam characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

Thermal aspects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50<br />

Module cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50<br />

Passive and active cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51<br />

Fan connection and temperature measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53<br />

Ordering information and sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

Article numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br />

Product applications and partners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br />

Tridonic sales organisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64<br />

Additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 3 / 68 -


&nbsp Introduction<br />

Description<br />

A new era has dawned with TALEXX LEDs. Now, high-quality light and optimum efficiency are no longer<br />

mutually exclusive. The versatile system solutions from Tridonic provide the basis for lighting designs that<br />

are futureproof, economical and eco-friendly in a wide range of applications. LEDs are showing their<br />

strengths in retail outlets, offices, hotels, restaurants and museums.<br />

If you are designing a luminaire to work with LEDs there are certain differences compared to designs with<br />

conventional light sources that you need to be aware of. We have written this design guide to help you<br />

understand these differences. It answers all the most important questions you may have, such as the<br />

right mechanical design, thermal management and optical conditions.<br />

Complete system solution<br />

LEDs offer major benefits for general illumination tasks - they are versatile, highly energy-efficient and<br />

virtually maintenance-free. With <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> you get a complete system solution<br />

for downlights from a single source, consisting of three perfectly matched components: LED module, LED<br />

converter and ready-made cables for connecting the module and the converter.<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> offers impressive benefits:<br />

High system efficiency of up to 115 lm/W at tp=65°C<br />

High module efficiency of up to 145 lm/W<br />

Excellent colour rendering (CRI > 90)<br />

Standardised lumen packages for precise lighting planning<br />

Integrated interfaces such as DALI<br />

High reproducible colour quality<br />

High life time 50,000 hours at L80 (tc=65°C)<br />

Compliance with the mechanical and electrical standards of the luminaire industry<br />

Please note:<br />

All information in this guide has been produced with the utmost care.<br />

However, the guide is subject to change without notice. Errors and omission excepted.<br />

Tridonic does not accept liability for possible damage resulting from the use of this guide.<br />

The latest version of this guide can be found at led.tridonic.com or from your sales<br />

partner.<br />

Creative freedom<br />

With one product you can cover a very wide range of lighting tasks that up to now would have been<br />

impossible because of the dimensions or thermal management of traditional light sources. The broad<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> portfolio offers the right solution for any application. You can find the<br />

right functionality to meet any requirements - from the non-dimmable basic version in different white<br />

tones to fully controllable and dimmable white light. In addition, there are special light colours available,<br />

for example for presenting fresh produce, meat and bread, and specific colours from the RGB spectrum.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 4 / 68 -


&nbsp Introduction<br />

Perfect white light<br />

A uniform crystal clear colour impression is very important particularly for wide-area lighting. TALEXX<br />

LEDs with their exceptional white light quality, their high luminous efficacy and their balanced distribution<br />

of light give luminaire designers a completely new tool. They provide instant light, free of ultra-violet or<br />

infra-red radiation, and constant colour.<br />

Excellent economy<br />

Compared with a lighting installation equipped with conventional light sources, TALEXX LEDs reduce<br />

energy consumption by up to 40 percent, and their long life significantly reduces maintenance and repair<br />

costs.<br />

Discover the new world of light with TALEXX LEDs.<br />

...<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 5 / 68 -


&nbsp Summary of the chapters<br />

Summary of the chapters<br />

To make it easier to find your way around the Design-in Guide we have grouped the information on the<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> systems into chapters.<br />

The guide begins with a system overview in which the different versions of the system are presented.<br />

The mechanical, electronic, optical and thermal aspects of the components are then described. At the<br />

end of the Design-in Guide you will find ordering information and sources.<br />

System overview<br />

The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> system is available in different versions, namely <strong>SELECT</strong>,<br />

CLASSIC and Food Colour with different properties and functions. The relevant components can be<br />

clearly assigned by their type codes.<br />

Mechanical aspects<br />

Depending on the particular situation, the converters can be installed in the luminaire casing (in-built) or<br />

outside the casing (remote). Dimensional drawings and installation instructions will help you take account<br />

of the requirements of the particular situation.<br />

Electrical aspects<br />

Standard cables can be used for the connection between the modules and the converter.<br />

All the connection options, the connections between the converter and the power supply and the<br />

connections of the control lines are shown in relevant wiring diagrams.<br />

Optical aspects<br />

The overall efficiency of the system is improved by choosing a reflector with suitable optical properties<br />

(e.g. beam angle) and dimensions.<br />

This chapter provides information to support customer-specific reflector design.<br />

Thermal aspects<br />

The system modules have been designed to operate with a passive or active heat sink and can be<br />

mounted directly on such a suitable heat sink.<br />

In the case of active cooling the fan can be connected directly to the module or converter depending on<br />

the version.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 6 / 68 -


&nbsp System Overview<br />

Ordering information and sources<br />

The ordering information for the components and the sources for heat sinks, reflectors and accessories<br />

can be found at the end of the document.<br />

System overview<br />

One system - three versions<br />

The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> system is available in three different versions:<br />

Properties and functions <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

Food Colour GOLD<br />

<strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

<strong>SELECT</strong><br />

<strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

CLASSIC<br />

Colour temperature 2,700 K 4,000 K, 3,000 K 5,000 K, 4,000 K,<br />

3,000 K<br />

Luminous flux at tp=65°C 1,400 lm bis 2,700 lm 1,050 lm to 3,250 lm 1,250 lm to 5,550 lm<br />

Colour rendering /<br />

colour tolerance<br />

System efficiency at<br />

tp=65°C<br />

CRI > 90 / MacAdam 3<br />

SDC<br />

DALI Device Type 6<br />

for converters with<br />

dimming function<br />

switchDIM for converters with<br />

dimming function<br />

up to CRI > 90 /<br />

MacAdam 3 SDCM<br />

CRI > 80 / MacAdam<br />

3 SDCM<br />

up to 77 lm/W up to 90 lm/W up to 115 lm/W<br />

Device Type 6<br />

for converters with<br />

dimming function<br />

for converters with<br />

dimming function<br />

Device Type 6<br />

for converters with<br />

dimming function<br />

for converters with<br />

dimming function<br />

Module efficiency 95 lm/W up to 115 lm/W up to 145 lm/W<br />

Components<br />

A uniform naming concept has been adopted for the components. The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong><br />

<strong>GEN2</strong> system (spotlight LED Engine) comprises the following components:<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong>, TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC and<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food colour GOLD: The modules (light sources) differ<br />

according to the version.<br />

TALEXXconverter Suitable LED converters with various functions are available for operating the<br />

modules.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 7 / 68 -


&nbsp System Overview<br />

Notice<br />

To ensure efficient and reliable operation, the modules should only ever be used with<br />

Tridonic converters.<br />

Efficiency of the modules<br />

The high efficiency of TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> results not only in energy savings but also to a<br />

reduction in the thermal load. This means that smaller heat sinks can be used and more compact<br />

luminaires can be designed.<br />

Area of application<br />

All the components of the <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> system comply with the protection<br />

requirements of IP20. The system is therefore suitable for indoor applications.<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> complies with system protection class II.<br />

The TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> modules meet the requirements of protection class III.<br />

Type codes and versions<br />

Type code for modules<br />

The following type code is used to identify the modules:<br />

Type code for modules for <strong>SLE</strong> G2 LES 19 930 SEL for example<br />

Reference <strong>STARK</strong> - <strong>SLE</strong><br />

<strong>GEN2</strong><br />

- LES<br />

19<br />

Meaning Produkt Form Size CRI<br />

> 90<br />

Type code for converters<br />

The following type code is used to identify the converters:<br />

- 9 30 - SEL<br />

Colour<br />

temperature<br />

3,000 K<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 8 / 68 -<br />

Version


&nbsp System Overview<br />

Type code for converters for LCI 050/1050 ... or example<br />

Reference LCI 050 / 1050<br />

Meaning LED converter,<br />

constant current<br />

...<br />

Power in W Current in mA<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 9 / 68 -


&nbsp System Overview<br />

Versions<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC<br />

The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC system is an attractive entry-level solution for general<br />

illumination with LEDs. TALEXXconverters with or without a dimming function are available depending on<br />

the application.<br />

Charakteristics:<br />

Colour temperature of 3,000 K, 4,000 K or 5,000 K<br />

Colour rendering index CRI > 90<br />

Lumen values: 1,300 lm to 5,300 lm<br />

Small MacAdam 3 SDCM colour tolerance<br />

System efficiency of up to 115 lm/W at tp=65°C with high energy savings<br />

Option for operating a 12 V active cooling system<br />

Temperature monitoring in conjunction with dimmable converters<br />

High module efficiency of up to 145 lm/W<br />

Control functions:<br />

On/off via mains with converter without dimming function<br />

DALI, with converter with dimming function<br />

The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC version can be combined as follows:<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 10 / 68 -


&nbsp System Overview<br />

Converter matrix <strong>SLE</strong> <strong>GEN2</strong> LES19 CLASSIC<br />

TALEXXconverter without dimming function<br />

Converter for an operating mode of 350 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

750 CLA<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

750 CLA<br />

Colour<br />

temperature<br />

In-built Remote<br />

1,450 lm 3,000 K LCCI 016/0350<br />

Q010<br />

LCI 015/0350<br />

E020<br />

1,600 lm 4,000 K LCCI 016/0350<br />

Q010<br />

LCI 015/0350<br />

E020<br />

1,750 lm 5,000 K LCCI 016/0350<br />

Q010<br />

LCI 015/0350<br />

E020<br />

Colour<br />

temperature<br />

LCCI<br />

016/0350<br />

B020<br />

LCI 015/0350<br />

M020<br />

LCCI<br />

016/0350<br />

B020<br />

LCI 015/0350<br />

M020<br />

LCCI<br />

016/0350<br />

B020<br />

LCI 015/0350<br />

M020<br />

In-built Remote<br />

2,700 lm 3,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

3,000 lm 4,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

3,250 lm 5,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 11 / 68 -


&nbsp System Overview<br />

TALEXXconverter with dimming function<br />

Converter for an operating mode of 350 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

750 CLA<br />

Converter for an operating mode of 500 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

750 CLA<br />

Colour<br />

temperature<br />

In-built Remote<br />

1,450 lm 3,000 K LCAI 015/0350<br />

A020<br />

1,600 lm 4,000 K LCAI 015/0350<br />

A020<br />

1,750 lm 5,000 K LCAI 015/0350<br />

A020<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,000 lm 3,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

2,250 lm 4,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

2,400 lm 5,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 12 / 68 -<br />

-<br />

-<br />

-


&nbsp System Overview<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

750 CLA<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,700 lm 3,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

3,000 lm 4,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

3,250 lm 5,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

Converter matrix <strong>SLE</strong> <strong>GEN2</strong> LES23 CLASSIC<br />

TALEXXconverter without dimming function<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

750 CLA<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,850 lm 3,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

3,150 lm 4,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

3,400 lm 5,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 13 / 68 -<br />

-<br />

-<br />

-<br />

LCI 030/0700<br />

M120<br />

LCI 030/0700<br />

M120<br />

LCI 030/0700<br />

M120


&nbsp System Overview<br />

Converter for an operating mode of 1,050 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

750 CLA<br />

TALEXXconverter with dimming function<br />

Converter for an operating mode of 500 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

750 CLA<br />

Colour<br />

temperature<br />

In-built Remote<br />

4,050 lm 3,000 K LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

R010<br />

4,450 lm 4,000 K LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

R010<br />

4,850 lm 5,000 K LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

R010<br />

Colour<br />

temperature<br />

In-built Remote<br />

LCI 050/1050<br />

T020<br />

LCI 050/1050<br />

T020<br />

LCI 050/1050<br />

T020<br />

2,100 lm 3,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

2,300 lm 4,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

2,500 lm 5,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 14 / 68 -


&nbsp System Overview<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

750 CLA<br />

Converter for an operating mode of 1,050 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

750 CLA<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,850 lm 3,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

3,150 lm 4,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

3,400 lm 5,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

Colour<br />

temperature<br />

In-built Remote<br />

4,050 lm 3,000 K LCAI 0050/1050<br />

N020<br />

DALI<br />

4,450 lm 4,000 K LCAI 0050/1050<br />

N020<br />

DALI<br />

4,850 lm 5,000 K LCAI 0050/1050<br />

N020<br />

DALI<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 15 / 68 -<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-


&nbsp System Overview<br />

Converter matrix <strong>SLE</strong> <strong>GEN2</strong> LES26 CLASSIC<br />

TALEXXconverter without dimming function<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

750 CLA<br />

Converter for an operating mode of 1,050 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

750 CLA<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,950 lm 3,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

3,250 lm 4,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

3,500 lm 5,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

Colour<br />

temperature<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

In-built Remote<br />

4,200 lm 3,000 K LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

R010<br />

4,650 lm 4,000 K LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

R010<br />

5,050 lm 5,000 K LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

R010<br />

LCI 050/1050<br />

T020<br />

LCI 050/1050<br />

T020<br />

LCI 050/1050<br />

T020<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 16 / 68 -


&nbsp System Overview<br />

Converter for an operating mode of 1,400 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

750 CLA<br />

TALEXXconverter with dimming function<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

750 CLA<br />

Colour<br />

temperature<br />

In-built Remote<br />

5,400 lm 3,000 K - LCI 055/1400<br />

R010<br />

5,950 lm 4,000 K - LCI 055/1400<br />

R010<br />

6,450 lm 5,000 K - LCI 055/1400<br />

R010<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,950 lm 3,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

3,250 lm 4,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

3,500 lm 5,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 17 / 68 -


&nbsp System Overview<br />

Converter for an operating mode of 1,050 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

750 CLA<br />

...<br />

Colour<br />

temperature<br />

In-built Remote<br />

4,200 lm 3,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

4,650 lm 4,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

5,050 lm 5,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 18 / 68 -<br />

-<br />

-<br />

-


&nbsp System Overview<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong><br />

The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> system is impressive for its highquality light.<br />

TALEXXconverters with or without a dimming function are available depending on the application.<br />

Charakteristics:<br />

Colour temperature of 3,000 K, 4,000 K<br />

Colour rendering index CRI > 90<br />

Excellent quality of light<br />

Lumen values: 1,100 lm to 3,350 lm<br />

Very small MacAdam 3 SDCM colour tolerance<br />

System efficiency of up to 90 lm/W with high energy savings at tp=65°C<br />

Option for operating a 12 V active cooling system<br />

Temperature monitoring in conjunction with dimmable converters<br />

Control functions:<br />

On/off via mains with converter without dimming function<br />

DALI, with converter with dimming function<br />

The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> version can be combined as follows:<br />

Converter matrix <strong>SLE</strong> <strong>GEN2</strong> LES19 <strong>SELECT</strong><br />

TALEXXconverter without dimming function<br />

Converter for an operating mode of 350 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

940 SEL<br />

Colour<br />

temperature<br />

In-built Remote<br />

1,300 lm 3,000 K LCCI 016/0350<br />

Q010<br />

LCI 015/0350<br />

E020<br />

1,300 lm 4,000 K LCCI 016/0350<br />

Q010<br />

LCI 015/0350<br />

E020<br />

LCCI<br />

016/0350<br />

B020<br />

LCI 015/0350<br />

M020<br />

LCCI<br />

016/0350<br />

B020<br />

LCI 015/0350<br />

M020<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 19 / 68 -


&nbsp System Overview<br />

TALEXXconverter with dimming function<br />

Converter for an operating mode of 350 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

940 SEL<br />

Converter for an operating mode of 500 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

940 SEL<br />

Colour<br />

temperature<br />

In-built Remote<br />

1,300 lm 3,000 K LCAI 015/0350<br />

A020<br />

1,300 lm 4,000 K LCAI 015/0350<br />

A020<br />

Colour<br />

temperature<br />

In-built Remote<br />

1,750 lm 3,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

1,750 lm 4,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

Converter matrix <strong>SLE</strong> <strong>GEN2</strong> LES23 <strong>SELECT</strong><br />

TALEXXconverter without dimming function<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

940 SEL<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,500 lm 3,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

2,600 lm 4,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 20 / 68 -<br />

-<br />

-<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010


&nbsp System Overview<br />

TALEXXconverter with dimming function<br />

Converter for an operating mode of 500 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

940 SEL<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

940 SEL<br />

Colour<br />

temperature<br />

In-built Remote<br />

1,800 lm 3,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

1,900 lm 4,000 K - LCAI 020/0500<br />

A120<br />

one4all<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,500 lm 3,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

2,600 lm 4,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

Convertermatrix <strong>SLE</strong> <strong>GEN2</strong> LES26 <strong>SELECT</strong><br />

TALEXXconverter without dimming function<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

940 SEL<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,550 lm 3,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

2,700 lm 4,000 K LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 21 / 68 -<br />

-<br />

-<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010


&nbsp System Overview<br />

Converter for an operating mode of 1,050 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

830 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

840 SEL<br />

TALEXXconverter with dimming function<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

940 SEL<br />

Converter for an operating mode of 1,050 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

830 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

840 SEL<br />

...<br />

Colour<br />

temperature<br />

In-built Remote<br />

3,700 lm 3,000 K LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

R010<br />

3,900 lm 4,000 K LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

R010<br />

Colour<br />

temperature<br />

LCI 050/1050<br />

T020<br />

LCI 050/1050<br />

T020<br />

In-built Remote<br />

2,550 lm 3,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

2,700 lm 4,000 K LCAI 030/0700<br />

A120<br />

one4all<br />

Colour<br />

temperature<br />

In-built Remote<br />

3,700 lm 3,000 K LCAI 0050/1050<br />

N020<br />

DALI<br />

3,900 lm 4,000 K LCAI 0050/1050<br />

N020<br />

DALI<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 22 / 68 -<br />

-<br />

-<br />

-<br />

-


&nbsp System Overview<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD<br />

The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD system is impressive for its high quality light.<br />

TALEXXconverters with or without a dimming function are available depending on the application.<br />

Charakteristics:<br />

Colour temperature of 2,700 K<br />

Colour rendering index CRI > 90<br />

Excellent quality of light<br />

Lumen values: 1,400 lm to 2,700 lm<br />

Very small MacAdam 3 SDCM colour tolerance<br />

System efficiency of up to 77 lm/W with high energy savings at tp=65°C<br />

Option for operating a 12 V active cooling system<br />

Temperature monitoring in conjunction with dimmable converters<br />

Control functions:<br />

On/off via mains with converter without dimming function<br />

DALI, with converter with dimming function<br />

The <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD version can be combined as follows:<br />

Converter matrix <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD<br />

TALEXXconverter without dimming function<br />

Converter for an operating mode of 500 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

GOLD SEL<br />

Colour<br />

temperature<br />

In-built Remote<br />

1,600 lm 2,700 K - LCI 20W 500mA<br />

TEC SR<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 23 / 68 -


&nbsp System Overview<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

GOLD SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

GOLD SEL<br />

Converter for an operating mode of 1,050 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

GOLD SEL<br />

TALEXXconverter with dimming function<br />

Converter for an operating mode of 500 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

GOLD SEL<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,150 lm 2,700 K - LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

LCI 35W 700mA<br />

TEC SR<br />

2,200 lm 2,700 K - LCI 030/0700<br />

E020<br />

LCI 030/0700<br />

A120<br />

LCI 030/0700<br />

M120<br />

LCI 033/0700<br />

U010<br />

LCI 35W 700mA<br />

TEC SR<br />

Colour<br />

temperature<br />

In-built Remote<br />

3,150 lm 2,700 K LCI 050/1050<br />

R010<br />

Colour<br />

temperature<br />

In-built Remote<br />

LCI 050/1050<br />

N020<br />

LCI 050/1050<br />

T020<br />

1,600 lm 2,700 K - LCAI 020/0500<br />

A120 one4all<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 24 / 68 -


&nbsp System Overview<br />

Converter for an operating mode of 700 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

GOLD SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

GOLD SEL<br />

Converter for an operating mode of 1,050 mA<br />

TALEXXmodule Luminous flux at<br />

tp=25°C<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

GOLD SEL<br />

...<br />

Colour<br />

temperature<br />

In-built Remote<br />

2,150 lm 2,700 K - LCAI 030/0700<br />

A120 one4all<br />

2,200 lm 2,700 K - LCAI 030/0700<br />

A120 one4all<br />

Colour<br />

temperature<br />

In-built Remote<br />

3,150 lm 2,700 K - LCAI 0050/1050<br />

N020 DALI<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 25 / 68 -


&nbsp System Overview<br />

Standards and directives<br />

Standards and directives for modules<br />

The following standards and directives were taken into consideration in designing and manufacturing the<br />

modules:<br />

CE<br />

2006/95/EG Low-voltage directive: Directive relating to electrical equipment for use<br />

within certain voltage limits<br />

2004/108/EG EMC* directive: Directive relating to electromagnetic compatibility<br />

RoHS<br />

2002/95/EC RoHS*-Directive: Directive on the restriction of the use of certain<br />

hazardous substances in electrical and electronic equipment<br />

* RoHS: Restriction of (the use of certain) hazardous substances<br />

Safety<br />

DIN IEC 62031:2008 Safety requirements for LED modules<br />

EN 60598-1:2008 und<br />

A11:2009<br />

EN 60598-2-2:1996 und<br />

A1:1997<br />

General requirements and tests for luminaires<br />

Luminaires - Part 2. Special requirements;<br />

Main section 2: Recessed luminaires<br />

EN 62471:2008 Photo-biological safety of lamps and lamp systems<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 26 / 68 -


&nbsp System Overview<br />

Safety and performance<br />

EN 61347-1:2009 General and safety requirements<br />

EN 61347-2-13:2007 Special requirements for dc and ac powered electronic operating<br />

equipment for LED modules<br />

EN 62384:2007 IEC<br />

62384 A1:2009<br />

Operational requirements<br />

Standards and directives for converters<br />

The following standards and directives were taken into consideration in designing and manufacturing the<br />

converters:<br />

EMI<br />

EN 55015 2008 Limit values measurement methods for radio interference properties of<br />

electrical lighting equipment and similar electrical devices<br />

EN 61000-3-2:2005 A1:<br />

2008 und A2:2009<br />

Limit values for harmonic currents (equipment input current < 16 A per<br />

conductor)<br />

EN 61000-3-3:2005 Limit values for voltage fluctuations and flicker in low-voltage systems for<br />

equipment with an input current < 16 A per conductor that are not<br />

subject to any special connection conditions<br />

EN 61547:2001 EMC* requirements<br />

EN 55015:2006 A1 2007 Limit values measurement methods for radio interference properties of<br />

electrical lighting equipment and similar electrical devices<br />

EN 61347-1:2008 General and safety requirements for equipment for lamps<br />

* EMC: Electromagnetic compatibility<br />

Safety<br />

EN 50172 2005 Safety lighting systems<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 27 / 68 -


&nbsp System Overview<br />

DALI<br />

IEC 62386-101:2009 General requirements, system<br />

IEC 62386-102:2009 General requirements, controller<br />

IEC 62386-207:2009 Special requirements, controller; LED modules<br />

...<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 28 / 68 -


&nbsp Mechanical Aspects<br />

Mechanical aspects<br />

Installation<br />

Installation versions<br />

EOS/ESD safety guidelines<br />

The device/module contains components that are sensitive to electrostatic discharge and<br />

may only be installed in the factory and on site if appropriate EOS/ESD protection<br />

measures have been taken. No special measures need be taken for devices/modules<br />

with enclosed casings (contact with the pc board not possible), just normal installation<br />

practice.<br />

Please note the requirements set out in the document EOS/ESD guidelines<br />

(Guideline_EOS_ESD.pdf) at:<br />

www.tridonic.com/com/en/technical-docs.asp<br />

Depending on the particular situation, the converters can be installed in the luminaire casing (in-built) or<br />

outside the casing (remote).<br />

In-built version Remote version<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 29 / 68 -


&nbsp Mechanical Aspects<br />

Integrated terminal for a<br />

time-saving assembly<br />

...<br />

Back of the module for thermal<br />

connection to the heat sink<br />

Version without housing for<br />

individual integration in the light<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 30 / 68 -


&nbsp Mechanical Aspects<br />

Notes on installation<br />

Depending on the installation situation for the converter and the modules, the following requirements<br />

must be met:<br />

Adequate distance from insulating materials<br />

Adequate strain relief for closed covering on the converter<br />

Adequate cooling of the modules (the maximum temperature at the tc point must not be exceeded)<br />

Unrestricted exit of light from the modules<br />

Protection measures against damage<br />

Mechanical stress<br />

TALEXX modules contain electronic components that are sensitive to mechanical stress. Such stress<br />

should be kept to an absolute minimum. In particular the following mechanical stresses should be<br />

avoided as these may cause irreversible damage:<br />

Pressure<br />

Bending stress<br />

Drilling,<br />

Milling,<br />

Breaking,<br />

Sawing,<br />

and similar mechanical processing.<br />

Compressive stresses<br />

The components of the TALEXX modules (circuit boards, glob-top, lenses, electronic components etc.)<br />

are sensitive to compressive stresses. The components must not be exposed to compressive stresses.<br />

If glass or Plexiglas shields are used make sure that pressure is not exerted on the glob-top.<br />

Only touch the TALEXX modules at the edges<br />

correct (left) and incorrect (right)<br />

Bending stress<br />

Bending the circuit board of a TALEXX module by more than 3 % along its length may damage the<br />

product and is therefore not permitted. 3 % corresponds for example to 6 mm for a 200 mm long module.<br />

Max. bending stress for LED strip modules<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 31 / 68 -


&nbsp Mechanical Aspects<br />

Handling of chemical substances<br />

Chemical substances are present in the vicinity of TALEXX modules in a wide range of applications.<br />

Below are the known areas in which chemical substances are used:<br />

use of protective coating in applications with high<br />

relative humidity (outdoor applications),<br />

encapsulation of LED modules,<br />

cementing of LED modules,<br />

sealing of luminaires.<br />

Protection measures for the glob top material<br />

The following guidelines must be observed to avoid damage to the glob-top:<br />

Make sure that the chemicals used in LED applications are not solvent-based, condensation<br />

crosslinked or acetate crosslinked (acetic acid). These give rise to reagents (e.g. solvent vapors,<br />

acetic acid) that may damage TALEXX module or the glob-top. This applies to chemicals that are<br />

used not in the immediate vicinity of the modules (e.g. seals) and also to chemicals that come into<br />

direct contact with the modules (e.g. insulating coatings, adhesives).<br />

powerLED P211, original powerLED P211,<br />

damaged by dissolver waste gas<br />

Protection measures in regards to sealing<br />

The points above also apply to chemicals used for sealing luminaire casings. If however the TALEXX<br />

module is not installed in the luminaire until after the sealing compound has been completely cured (see<br />

relevant material information) the above points can be ignored.<br />

If the TALEXX modules have already been installed in the luminaire, possible damage to the glob-top can<br />

be reduced to a minimum by ensuring adequate spacing (>10 cm) and ventilation (open casing and air<br />

circulation, extraction / fan) during the curing process.<br />

Protection measures in regards to cementing<br />

To avoid damaging the TALEXX modules you must not use any tools or exert any pressure on the<br />

electronic components or the glob top.<br />

If glass or Plexiglas shields are used make sure that pressure is not exerted on the glob-top.<br />

Only touch the TALEXX modules at the edges<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 32 / 68 -


&nbsp Mechanical Aspects<br />

Instructions for cementing TALEXX modules<br />

Preparation<br />

Clean and durable bonding of two materials requires special attention.<br />

The following cleaning agents are recommended:<br />

Isopropanol / Water 50/50<br />

Acetone<br />

Heptane<br />

Important aspects<br />

Carrier material<br />

The carrier material must have adequate thermal conductivity (e.g. aluminium). The size of the<br />

cooling surface depends on the power of the LEDs, among other things. For information on the<br />

cooling surface required, see the appropriate product data sheet.<br />

Adhesive material<br />

The carrier material itself plays an important role in selecting the adhesive material. The crucial<br />

factors are the coefficient of expansion and compatibility with the base material of the TALEXX<br />

module board (plastic or aluminium). This must be checked in the application in terms of long-term<br />

stability, surface contamination and mechanical properties.<br />

Surface quality<br />

The carrier material must be uncoated (thermal transport, adhesion) and level at the connection<br />

points.<br />

Installation temperature<br />

To achieve optimum adhesion we recommend you carry out this work at room temperature.<br />

Duration, optimum adhesive strengths<br />

Maximum adhesion is achieved within 48 hours at room temperature; the process is accelerated<br />

by heat. In actual practice this means that at the maximum tc temperature (approx. 75-85 °C,<br />

product-specific) maximum adhesion is reached after about 12 hours. During the curing period<br />

make sure that there is no tensile load on the adhesive connection of the TALEXX module.<br />

Additional information<br />

TALEXX modules must not be stuck and restuck time and again without replacing the adhesive tape.<br />

Damaged adhesive tapes must be completely removed and replaced by new tapes.<br />

Packaging and transport<br />

TALEXX products from Tridonic are delivered in appropriate packaging. The packaging provides special<br />

protection against mechanical damage and ESD (electrostatic discharge). If you need to transport<br />

TALEXX products you should use this packaging.<br />

Installing the modules<br />

The modules are mounted on a heat sink with 2 bolts per module. In order not to damage the modules<br />

only raised head bolts should be used. The bolts should be selected on the basis of the following<br />

dimensions:<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 33 / 68 -


&nbsp Mechanical Aspects<br />

Dimensions of the fastening bolts<br />

Bolt size M3 *<br />

Max. diameter D 5.8 mm<br />

Min. length L 10 mm<br />

Max. length L Depending on the design of the<br />

luminaire and the heat sink<br />

Max. bolt head height k 1.3 mm for flat reflectors,<br />

higher values for steep reflectors<br />

* Use M3 bolts according to DIN 84 (ISO 1207, UNI 6107).<br />

Different bolt head heights<br />

Flat reflectors Steep reflectors<br />

The bolt head height of flat reflectors must not<br />

exceed a maximum of 1.3 mm.<br />

Further information<br />

The bolt head height of steep reflectors can be<br />

more than 1.3 mm.<br />

Detailed information on the thermal connection and the position of the t point is given at<br />

c<br />

"Thermal aspects".<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 34 / 68 -


&nbsp Mechanical Aspects<br />

Dimensional drawings<br />

Dimensional drawing of the modules TALEXXmodule <strong>STARK</strong><br />

<strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> and TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

CLASSIC<br />

With housing<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 35 / 68 -


&nbsp Mechanical Aspects<br />

Without housing<br />

Further information<br />

CAD data for the modules can be downloaded from the Tridonic homepage (www.tridonic<br />

.com)<br />

and the relevant product page.<br />

Remote converters for TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

<strong>SELECT</strong>, CLASSIC and Food Colour GOLD<br />

Length L max. 207 mm<br />

Width W max. 42 mm<br />

Height H max. 31 mm<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 36 / 68 -


&nbsp Mechanical Aspects<br />

In-built converter for <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong>,<br />

CLASSIC and Food Colour GOLD<br />

Length L max. 123 mm<br />

Width W max. 79 mm<br />

Height H max. 31 mm<br />

...<br />

Further information<br />

Detailed information and CAD data for the converters can be downloaded from the<br />

Tridonic homepage www.tridonic.com and the relevant product page.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 37 / 68 -


&nbsp Electrical Aspects<br />

Electrical aspects<br />

Electrical connections<br />

Electrical safety<br />

All the components of the <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> system comply with the SELV standard.<br />

The voltages are therefore less than 50 V.<br />

Safety extra low voltage (SELV) is defined as ac voltages up to 50 V rms and dc voltages up to 120 V.<br />

SELV is part of the low-voltage range. These voltages are not life-threatening to an adult and correspond<br />

to the maximum constant contact voltage or fault voltage.<br />

Thanks to SELV voltage, the luminaire can be replaced without risk. There is no need in this case to<br />

disconnect the luminaire from the power supply.<br />

Screw terminals on the converter<br />

The connections between the converter and the power supply and the connections of the control lines<br />

are made via screw terminals on the converter.<br />

Screw size M3<br />

Max. torque 0.5 nm<br />

Diameter of the cables for strain relief 6.3 to 9.7 mm<br />

Permissible cable cross-section for terminal: 0.5-2.5 mm²<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 38 / 68 -


&nbsp Electrical Aspects<br />

Connections on the converter<br />

Connections on the converter for TALEXXmodule <strong>STARK</strong> <strong>SLE</strong><br />

<strong>GEN2</strong> <strong>SELECT</strong> and TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC<br />

Pin Connection on the TALEXXconverter Design<br />

Function earth Screw<br />

terminal<br />

~ Power input 230 – 240 V AC Screw<br />

terminal<br />

~ Power input 230 – 240 V AC Screw<br />

terminal<br />

DA* Control input for DALI / switchDIM Screw<br />

terminal<br />

DA* Control input for DALI / switchDIM Screw<br />

terminal<br />

+FAN Feed for active cooling Screw<br />

terminal<br />

-FAN Feed for active cooling Screw<br />

terminal<br />

+LED TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> /<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC /<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour<br />

GOLD<br />

-LED TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> /<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC /<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour<br />

GOLD<br />

Screw<br />

terminal<br />

Screw<br />

terminal<br />

NTC Temperature monitoring Screw<br />

terminal<br />

NTC Temperature monitoring Screw<br />

terminal<br />

* Only for converters with dimming function<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 39 / 68 -


&nbsp Electrical Aspects<br />

Wiring diagrams<br />

Wiring diagram for switchDIM for <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong><br />

<strong>GEN2</strong> <strong>SELECT</strong>, <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC and<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD<br />

The wiring diagram shows the connection between a converter and a TALEXXmodule <strong>STARK</strong> <strong>SLE</strong><br />

<strong>GEN2</strong> <strong>SELECT</strong>, TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC and TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

Food Colour GOLD module and the connection between the converter and the power supply.<br />

The integrated switchDIM function is operated via an appropriate momentary-action switch.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 40 / 68 -


&nbsp Electrical Aspects<br />

Wiring diagram for DALI for <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

<strong>SELECT</strong>, <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC and<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD<br />

The wiring diagram shows the connection between a converter with dimming function and a<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong>, TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC and<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD module and the connection between the<br />

converter and the power supply and the digital DALI signal.<br />

The converters with the dimming function of the systems <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong>,<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC and TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour<br />

GOLD support DALI Device Type 6.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 41 / 68 -


&nbsp Electrical Aspects<br />

Wiring diagram for ON/OFF via mains for <strong>TALEXXengine</strong> <strong>STARK</strong><br />

<strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong>, <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC<br />

and TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD<br />

The wiring diagram shows the connection between a converter without the dimming function and a<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong>, TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC and<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD and the connection between the converter and<br />

the power supply.<br />

...<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 42 / 68 -


&nbsp Optical Aspects<br />

Optical aspects<br />

Colour spectrum<br />

The Dam&Fill technology used in the TALEXX products enables LEDs to be produced in special light<br />

colours or colour temperatures. This means that lighting systems can be created that are not only<br />

energy-efficient but also have excellent colour rendering.<br />

3,000 K<br />

4,000 K<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 43 / 68 -


&nbsp Optical Aspects<br />

5,000 K<br />

Colour spectrum at different colour temperatures<br />

The diagram shows the normalised intensity in percent over the wavelength in nm at different colour<br />

temperatures.<br />

Coordinates and tolerances (to CIE 1931)<br />

As before, the production process for TALEXX LEDs does without binning. As a result, white LEDs can<br />

be produced with normal distribution in the range of a MacAdam-Ellipse 3. Thanks to the proximity to the<br />

Planckian curve there are no annoying colour discrepancies.<br />

Every module is automatically tested at the final inspection stage to ensure that all the supplied products<br />

fall within the agreed specification.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 44 / 68 -


&nbsp Optical Aspects<br />

Location of the measuring points along the Planckian curve:<br />

Ambient temperature<br />

of the measurement:<br />

Measurement tolerances<br />

of the colour<br />

coordinates:<br />

t = 25 °C.<br />

a<br />

±0,01.<br />

Coordinates and tolerances<br />

Light colours<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> are available in 3,000K, 4,000K, GOLD.<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC are available in 3,000K, 4,000K, 5,000K versions.<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD is available.<br />

MacAdam Ellipse: GOLD<br />

x0 y0<br />

Centre 0.4633 0.4169<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 45 / 68 -


&nbsp Optical Aspects<br />

MacAdam Ellipse: 3,000 K<br />

x0 y0<br />

Centre 0.4369 0.4041<br />

MacAdam Ellipse: 4,000 K<br />

x0 y0<br />

Centre 0.3804 0.3764<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 46 / 68 -


&nbsp Optical Aspects<br />

MacAdam Ellipse: 5,000 K<br />

x0 y0<br />

Centre 0.3451 0.3516<br />

Eye safety<br />

Risk group Evaluation<br />

Actinic UV E<br />

S<br />

(200 - 400 nm)<br />

Near UV E<br />

UVA<br />

(315 - 400 nm)<br />

Blue light L<br />

B<br />

(300 - 700 nm)<br />

Retina, thermal L<br />

R<br />

(380 - 1,400 nm)<br />

IR radiation, eye E<br />

IR<br />

(780 - 3,000 nm)<br />

Risk group 0*<br />

Risk group 0*<br />

Risk group 0*<br />

Risk group 0*<br />

Risk group 0*<br />

* The evaluation of eye safety is based on EN 62471:2008 (photo-biological safety of lamps and lamp<br />

systems):<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 47 / 68 -


&nbsp Optical Aspects<br />

systems):<br />

Risk-free (risk groups 0, 1, 2 and 3): The LEDs do not pose any photo-biological risk.<br />

Low risk: The LEDs pose a small risk because of normal limitations.<br />

Medium risk: The LEDs pose a small risk because of reactions to bright light sources or thermal<br />

discomfort.<br />

High risk: The LEDs pose a risk even with just momentary or temporary exposure.<br />

Reflector design and beam characteristics<br />

Reflektor design<br />

The mechanical and optical properties of the modules of the <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> system<br />

offer the best conditions for using reflectors. The overall efficiency of the system can be optimised by<br />

choosing a reflector that directs the light appropriately.<br />

The optical properties (e.g. beam angle) and the dimensions of the reflector play a crucial role.<br />

The overall height of the luminaire can be reduced by selecting a low-profile reflector, depending on the<br />

beam angle required. This may improve the thermal output of the luminaire by increasing the height<br />

available for the heat sink.<br />

To achieve uniform illumination a reflector withy an integrated diffuser is recommended for LED modules<br />

with multicolour LEDs. This ensures that the colours are properly mixed. Some reflectors have the option<br />

of faceting for the reflector wall. Depending on the position of the homogenising element, different<br />

efficiencies and different colour mixing results can be achieved.<br />

Examples of reflectors with different beam angles<br />

Further information<br />

Tridonic can supply the CAD data for the modules on request to help create customised<br />

designs and to carry out optical simulations.<br />

Sources for the reflectors are given at "Partners".<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 48 / 68 -


&nbsp Optical Aspects<br />

Beam characteristics, TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

Average illuminance referred to the lumen values of<br />

TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

Mounting height Diameter of the beam LES19 LES23 LES26<br />

0.25 m 0.65 m 4,180 lux 6,098 lux 9,044 lux<br />

0.5 m 1.30 m 1,045 lux 1,525 lux 2,261 lux<br />

0.75 m 1.94 m 464 lux 678 lux 1,005 lux<br />

1.0 m 2.59 m 261 lux 381 lux 565 lux<br />

...<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 49 / 68 -


&nbsp Thermal Aspects<br />

Thermal aspects<br />

Module cooling<br />

Effect of cooling on the life of the modules<br />

The modules of the<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> system have been designed to operate with a<br />

passive or active heat sink and can be mounted directly on such a suitable heat sink.<br />

The life of the module depends to a large extent on the operating temperature. The more that the<br />

operating temperature can be reduced by cooling, the longer the expected life of the module. If the<br />

permitted operating temperature is exceeded, however, the life of the module will be significantly<br />

reduced.<br />

Lifetime characteristic:<br />

The diagram shows the change in luminous flux in % over an operating time of 1,000 h at different tc<br />

operating temperatures.<br />

Luminous flux Operating time in HE mode at tp = 65 °C<br />

80 % 50,000 h<br />

70 % 80,000 h<br />

50 % 156,000 h<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 50 / 68 -


&nbsp Thermal Aspects<br />

Further information<br />

Please check the information on the operating temperature and the requirements for<br />

cooling in the module data sheets.<br />

Requirements for the heat sink<br />

Although the operating temperature of the modules is continually monitored during operation and the<br />

power is automatically reduced in the event of excess temperature, the modules should not be operated<br />

without a heat sink.<br />

The heat sinks must be dimensioned to provide adequate cooling capacity.<br />

The R value is important for selecting an appropriate heat sink. This value depends on the light output<br />

th<br />

of the module and on the ambient temperature in which the module is to be operated. The Rth value of<br />

the heat sink must be smaller than the required R value.<br />

th<br />

Further information<br />

Please check the information on heat sinks in the module data sheets.<br />

Sources for suitable heat sinks are given at "Partners".<br />

Passive and active cooling<br />

Passive cooling<br />

Passive cooling module Example of passive cooling for the module<br />

Heat transfer from a heat source to the surrounding cooling medium (e.g. air) depends primarily on the<br />

difference in temperature, the effective surface area and the flow rate of the cooling medium. The<br />

function of a heat sink is to increase the surface area over which the heat can be dissipated. This lowers<br />

the thermal resistance.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 51 / 68 -


&nbsp Thermal Aspects<br />

the thermal resistance.<br />

A passive heat sink works mainly by convection. The surrounding air is heated, which makes it rise, and<br />

is replaced by cooler air.<br />

Heat pipes can be used as an alternative to cooing with fans. If space is particularly tight, the heat is first<br />

conveyed away. The actual heat sink is located at the other end of the heat pipe.<br />

Benefits of passive cooling:<br />

Energy savings<br />

Silent<br />

No mechanical wear<br />

No maintenance<br />

Active cooling<br />

Round active cooling module<br />

round<br />

Square active cooling module Example of active cooling for the<br />

module<br />

An active heat sink consists of the heat sink itself and an electrically powered fan. The fan dissipates<br />

heat from the heat sink by blowing a sufficient quantity of air along the surface of the heat sink. To reduce<br />

the power draw and noise, the fan speed can be controlled from the active cooling system on the basis of<br />

temperature.* A diaphragm can be used as an alternative to fans to produce active air movements.<br />

Active heat sinks with fan cooling achieve around six times the performance of passive heat sinks for the<br />

same amount of material used. Active heat sinks can therefore be made very compact.<br />

* The fan speed is not controlled from the <strong>TALEXXengine</strong> <strong>STARK</strong> system.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 52 / 68 -


&nbsp Thermal Aspects<br />

Benefits of active cooling:<br />

Space savings<br />

Effective cooling<br />

Professional design<br />

Fan connection and temperature measurement<br />

Connections of the fan to the converter for TALEXXmodule<br />

<strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong>, TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong><br />

CLASSIC and TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour<br />

GOLD<br />

For active cooling of the TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong>, TALEXXmodule <strong>STARK</strong> <strong>SLE</strong><br />

<strong>GEN2</strong> CLASSIC and TALEXXmodule <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food Colour GOLD versions the fan is<br />

connected to the converter.<br />

Fan connection on the converter<br />

+FAN +<br />

-FAN -<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 53 / 68 -


&nbsp Thermal Aspects<br />

Temperature measurement on the module<br />

There is a t point underneath the modules for checking the temperature of the<br />

c<br />

modules:<br />

The temperature at the tc point can be measured with a simple temperature<br />

probe. Since the underside of the modules is made from anodised aluminium, any<br />

measurements made by an infra-red camera would lead to inaccurate results.<br />

In actual practice, thermocouples (e.g. B & B Thermotechnik thermocouple,<br />

K-type) have been successfully used for taking measurements. Such<br />

thermocouples can be attached directly to the tc point with heat-resistant adhesive<br />

tape or a suitable adhesive. The measured values are recorded by an electronic<br />

thermometer (e.g. "FLUKE 51", VOLTCRAFT K202 data logger).<br />

The maximum possible temperature must be determined under worst-case<br />

conditions (ambient temperature of the luminaire, installation of the luminaire) for<br />

the relevant application. Before the measurement is taken the luminaire should be<br />

operated for at least 4 hours in a draught-free room.<br />

Temperature management of the converters<br />

Although the converters have an integrated temperature management system the requirements relating<br />

to cooling of the converters must also be taken into account. Unintentional automatic dimming at<br />

overtemperature, for example, indicates inadequate cooling of the converter.<br />

The temperature at the t point on the converter can be measured with a simple temperature probe. The<br />

c<br />

tc point on the converter is indicated by a sticker on the casing.<br />

...<br />

Further information<br />

Measurement conditions, sensors and handling are described in detail in standard EN<br />

60598-1 “General requirements and tests for luminaires”.<br />

Sources for suitable heat-conducting foil and pastes for thermal connection to a<br />

temperature probe are given at "Partners".<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 54 / 68 -


&nbsp Ordering information and sources<br />

Ordering information and sources<br />

Article numbers<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC with LES19<br />

Product name Article number Description<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

750 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES19 830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES19 840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES19 750 CLA<br />

89601652 3,000 K<br />

89601632 4,000 K<br />

89601633 5,000 K<br />

89601622 3,000 K<br />

89601623 4,000 K<br />

89601624 5,000 K<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 55 / 68 -


&nbsp Ordering information and sources<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC with LES23<br />

Product name Article number Description<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

750 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES23 830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES23 840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES23 750 CLA<br />

89601634 3,000 K<br />

89601635 4,000 K<br />

89601636 5,000 K<br />

89601625 3,000 K<br />

89601626 4,000 K<br />

89601627 5,000 K<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> CLASSIC with LES26<br />

Product name Article number Description<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

750 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES26 830 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES26 840 CLA<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES26 750 CLA<br />

89601637 3,000 K<br />

89601638 4,000 K<br />

89601639 5,000 K<br />

89601628 3,000 K<br />

89601629 4,000 K<br />

89601630 5,000 K<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 56 / 68 -


&nbsp Ordering information and sources<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> with LES19<br />

Product name Article number Description<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES19<br />

940 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES19 930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES19 940 SEL<br />

89601660 3,000 K<br />

89601661 4,000 K<br />

89601669 3,000 K<br />

89601670 4,000 K<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> with LES23<br />

Product name Article number Description<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

940 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

MEAT+ SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

GOLD SEL<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES23 930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES23 940 SEL<br />

89601663 3,000 K<br />

89601664 4,000 K<br />

89601662<br />

89601665 2,700 K<br />

89601672 3,000 K<br />

89601673 4,000 K<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 57 / 68 -


&nbsp Ordering information and sources<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> <strong>SELECT</strong> with LES26<br />

Product name Article number Description<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

940 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

MEAT+ SEL<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

GOLD SEL<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES26 930 SEL<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES26 940 SEL<br />

...<br />

89601666 3,000 K<br />

89601667 4,000 K<br />

89601678 -<br />

89601668 2,700 K<br />

89601675 3,000 K<br />

89601676 4,000 K<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 58 / 68 -


&nbsp Ordering information and sources<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food colour GOLD with LES23<br />

Product name Article number Description<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES23<br />

GOLD<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES23 GOLD<br />

89601665 2,700 K<br />

89601674 2,700 K<br />

<strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> Food colour GOLD mit LES26<br />

Product name Article number Description<br />

<strong>STARK</strong> <strong>SLE</strong> G2 LES26<br />

GOLD<br />

<strong>STARK</strong> <strong>SLE</strong> PURE G2<br />

LES26 GOLD<br />

Suitable controllers<br />

89601668 2,700 K<br />

89601677 2,700 K<br />

Tridonic offers a comprehensive range of DALI-compatible products. All the devices specified here<br />

support DALI Device Type 6 and therefore guarantee effective use of <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong><br />

<strong>GEN2</strong>.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 59 / 68 -


&nbsp Ordering information and sources<br />

Product name Article number<br />

DALI M-Sensor 86458265<br />

DALI SC 24034263<br />

DALI MC 86458507<br />

DALI Touchpanel 24035465<br />

x-touchBOX 24138954<br />

x-touchPANEL 24138990<br />

DALI PS 24033444<br />

DALI USB 24138923<br />

Further information<br />

Go to www.tridonic.com to see the current range of products and the latest software<br />

updates.<br />

Product applications and partners<br />

Product application matrix<br />

Whether you are looking for wide-area lighting or focused accent lighting, our wide range of TALEXX<br />

products will help you create an individual atmosphere and highlight specific areas exactly as you want.<br />

Our product portfolio includes individual light points, round, rectangular and strip versions. Specially<br />

matched operating equipment such as converters, amplifiers and sequencers round off the components<br />

for a perfect system solution: They guarantee ideal operation and maximum efficiency.<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 60 / 68 -


&nbsp Ordering information and sources<br />

Luminaire application<br />

<strong>TALEXXengine</strong> Downlight Spotlight Linear /<br />

rectangular<br />

<strong>TALEXXengine</strong> <strong>STARK</strong><br />

DLE<br />

<strong>TALEXXengine</strong> <strong>STARK</strong><br />

<strong>SLE</strong><br />

<strong>TALEXXengine</strong><br />

FULMEN<br />

+<br />

+ + + +<br />

<strong>TALEXXengine</strong> LINE + +<br />

Luminaire application<br />

TALEXXmodule Downlight Spotlight Linear /<br />

rectangular<br />

+<br />

TALEXXmodule SPOT + + + +<br />

TALEXXmodule<br />

RECTANGULAR<br />

Decorative Surface Outdoor<br />

(street)<br />

Decorative Surface Outdoor<br />

(street)<br />

TALEXXmodule EOS + + + + + +<br />

TALEXXmodule STRIP + +<br />

TALEXXmodule TAPE + +<br />

For more information and technical data on the entire TALEXX product portfolio go to led.tridonic.com or<br />

see our TALEXX catalogue.<br />

...<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 61 / 68 -<br />

+


&nbsp Ordering information and sources<br />

Partners<br />

Heat sinks<br />

Heat sinks with active and passive cooling to match the module can be obtained from the following<br />

manufacturers:<br />

BRYTEC AG Brytec GmbH<br />

Vierthalerstrasse 5<br />

AT-5020 Salzburg<br />

T +43 662 87 66 93<br />

F +43 662 87 66 97<br />

info@brytec.at<br />

Nuventix<br />

Vertrieb Österreich<br />

EBV Distributor<br />

Schonbrunner Straße 297-307<br />

1120 Wien<br />

T +43 1 89152-0<br />

F +43 1 89152-30<br />

www.ebv.com<br />

SUNON European Headquarters<br />

Sales area manager<br />

Direct line: 0033 1 46 15 44 98<br />

Fax: 0033 1 46 15 45 10<br />

Mobile: 0033 6 24 07 50 49<br />

andreas.rudel@sunoneurope.com<br />

Heat sinks with active cooling can be obtained from the following manufacturers:<br />

Francois JAEGLE<br />

NUVENTIX EMEA Sales and Support Director<br />

+33 624 73 4646<br />

PARIS<br />

fjaegle@nuventix.com<br />

Heat sinks with passive cooling can be obtained from the following manufacturers:<br />

AVC<br />

Asia Vital Components Europa GmbH<br />

Willicher Damm 127<br />

D-41066 Mönchengladbach<br />

T +49 2161 5662792<br />

F +49 2161 5662799<br />

sales@avc-europa.de<br />

FrigoDynamics GmbH<br />

Bahnhofstr. 16<br />

D-85570 Markt-Schwaben<br />

Germany<br />

+49-8121-973730<br />

+49-8121-973731<br />

www.frigodynamics.com<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 62 / 68 -


&nbsp Ordering information and sources<br />

Reflector solutions and reflector design<br />

Reflector solutions and support for reflector design are available from the following partners:<br />

Alux-Luxar GmbH & Co. KG<br />

Schneiderstrasse 76<br />

40764 Langenfeld<br />

Germany<br />

T +49 2173 279 0<br />

sales@alux-luxar.de<br />

Jordan Reflektoren GmbH & Co. KG<br />

Schwelmerstrasse 161-171<br />

42389 Wuppertal<br />

Germany<br />

T +49 202 60720<br />

info@jordan-reflektoren.de<br />

LEDIL OY<br />

Tehdaskatu 13<br />

24100 Salo, Finland<br />

F +35 8 2 7338001<br />

Heat-conducting foil and paste<br />

Heat-conducting foil (e.g. Transtherm® T2022-4, or Transtherm® Phase Change) for thermal connection<br />

between the module and a heat sink is available from the following partner:<br />

BALKHAUSEN Division of Brady GmbH<br />

Rudolf-Diesel-Straße 17<br />

28857 Syke<br />

Postfach 1253, 28846, Syke<br />

T +49 4242 692 0<br />

F +49 4242 692 30<br />

angebot@balkhausen.de<br />

Heat-conducting paste (e.g. Silicone Fluid Component) for thermal connection between the module and a<br />

heat sink is available from the following partner:<br />

Shin-Etsu Chemical Co. Ltd.<br />

6-1, Ohtemachi 2-chome<br />

Chiyoda-ku<br />

Tokyo 100-0004<br />

Japan<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 63 / 68 -


&nbsp Ordering information and sources<br />

Tridonic sales organisation<br />

AUSTRALIA<br />

Tridonic Australia Pty Ltd<br />

Private Bag No. 9<br />

130 Melrose Drive, Tullamarine,<br />

Victoria, 3043<br />

Australia<br />

T +61 3 9339 0200<br />

F +61 3 9330 3595<br />

www.tridonic.com.au<br />

Tridonic Australia Pty Ltd<br />

P.O. Box 120<br />

Unit F1 Palm Grove Business<br />

Park<br />

13-15 Forrester Street<br />

Kingsgrove NSW 2208<br />

Australia<br />

T +61 2 9503 0800<br />

F +61 2 9503 0888<br />

www.tridonic.com.au<br />

AUSTRIA<br />

Tridonic GmbH & Co KG<br />

(Headquarters)<br />

Färbergasse 15<br />

6851 Dornbirn, Österreich<br />

T +43 5572 395-0<br />

F +43 5572 20176<br />

www.tridonic.com<br />

sales@tridonic.com<br />

Tridonic GmbH & Co KG Sales<br />

Austria<br />

Archenweg 58<br />

6022 Innsbruck, Österreich<br />

T +43 512 3321554<br />

F +43 512 3321-995554<br />

vertrieb.austria@tridonic.com<br />

www.tridonic-ct.com<br />

office@tridonic-ct.com<br />

BELGIUM<br />

Tridonic<br />

Sales Belgium<br />

39, Rue Gaston Bay<br />

1310 La Hulpe, Belgique<br />

T +32 2 652 1964<br />

F +32 2 652 0718<br />

pauwels.tridonic@skynet.be<br />

HONG KONG<br />

GLM International Limited<br />

Tridonic Sole Agent<br />

Hong Kong Unit 2205, Westin<br />

Centre<br />

26 Hung To Road,<br />

Kwun Tong, Kowloon, Hong<br />

Kong<br />

T +852 23983918<br />

F +852 23983911<br />

sales@glm.com.hk<br />

HUNGARY<br />

HOLUX Co. Ltd Lighting<br />

Systems Béké út. 51-55<br />

1135 Budapest, Hungary<br />

T +36 1 450 27 00<br />

F +36 1 450 27 10<br />

www.holux.hu<br />

sales usa@tridonic.com<br />

INDIA<br />

Atco Controls (India) Pvt. Ltd.<br />

38B Nariman Bhavan,<br />

Nariman Point<br />

Mumbai, 400 021, India<br />

T +91 22 2202 5528<br />

F +91 22 2203 2304<br />

sales@atcocontrols.com<br />

INDONESIA<br />

P.T. Sahabat Indonesia<br />

Jl Muara Karang Selatan Blok<br />

A, Utara 1<br />

Kawasan Industri<br />

Pergudangan<br />

Jakarta Utara 14440<br />

Indonesia<br />

T +62 21 661 0651 / 662<br />

1780<br />

F +62 21 660 3700<br />

sahabat@uninet.net.id<br />

RUSSIA<br />

TOCHKA OPORY Fakultetskij<br />

per. 12<br />

RU-125080 Moskow, Russia<br />

T +7 095 1581359<br />

F +7 095 1582433<br />

Michael.Ekassov@tridonic.com<br />

SINGAPORE<br />

Lumitron Pte Ltd<br />

103 Kaki Bukit Avenue 1,<br />

Shun Li Industrial Park,<br />

Singapore 415986<br />

T +65 6846 2288<br />

F +65 6846 2289<br />

Tridonic S.E.A Pte Ltd<br />

1 Kaki Bukit View<br />

#05-13, Techview<br />

Singapore 415941<br />

T +65 6292 8148<br />

F +65 6293 3700<br />

SLOVAKIA<br />

SCHÄFER & SYKORA spol.<br />

s.r.o. Cihlarska 1000/2<br />

40801 Rumburk<br />

Czech. Republic<br />

T +420 412 354 931<br />

F +420 412 354 945<br />

www.svetlosasa.cz<br />

svetlo@sasa.cz<br />

SLOVENIA<br />

ETT LIGHTING d.o.o. Dobrna 7<br />

3204 Dobrna, Slovenia<br />

T +386 3 7801070<br />

F +386 3 7801078<br />

www.ett-lighting.com<br />

info@ett-lighting.com<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 64 / 68 -


&nbsp Ordering information and sources<br />

BULGARIA<br />

ROS<br />

Rossiza Dontscheva<br />

Topolniza 1<br />

1510 Soia<br />

Bulgaria<br />

T: +359 2 943 42 32<br />

F: +359 2 945 73 62<br />

oice@ros-bg.com<br />

www.ros-bg.com<br />

CHILE<br />

GENERAL ELECTRIC DE CHILE<br />

SA Casilla 2103<br />

AV. VICUNA MACKENNA 2385<br />

7040060 Santiago, Chile<br />

T +56 24214224<br />

F +56 24214221<br />

flavio.gonzalez@lighting.ge.com<br />

CHINA<br />

Tridonic (Shanghai) Co., Ltd.<br />

(Headquarters)<br />

Building 3, 799 West Tianshan<br />

Road<br />

Shanghai, 200335, China<br />

T +86 21 52400599<br />

F +86 21 52400230<br />

china@tridonic.com<br />

Tridonic (Shanghai) Co.,<br />

Ltd. Beijing Branch<br />

Room 1217, Block B,<br />

COFCO Plaza No. 8 Jian Guo<br />

Men Nei Da Jie,<br />

Beijing, 100005, China<br />

T +86 10 65226163<br />

F +86 10 65227003<br />

china@tridonic.com<br />

Tridonic (Shanghai) Co.,<br />

Ltd. Guangzhou Branch<br />

505, R & F Profit Plaza,<br />

Huangpu Xi Road, Tianhe District<br />

Guangzhou, 510623, China<br />

T +86 20 38392483<br />

F +86 20 38392482<br />

china@tridonic.com<br />

ITALY<br />

Tridonic Italia srl<br />

viale della Navigazione<br />

Interna 115<br />

35027 Noventa Padovana<br />

(PD)<br />

T +39 049 89 45 127<br />

F +39 049 87 04 715<br />

www.tridonic.it<br />

vendite.italia@tridonic.com<br />

servizio.tecnico@tridonic.com<br />

Sicom Spa<br />

Via Lussemburgo, 10-12<br />

35127 Padova-Zona Ind.<br />

T +39 049 8701470<br />

F +39 049 8700738<br />

www.sicom-pd.it<br />

KOREA (SOUTH)<br />

One4all Lighting Co. Ltd<br />

#D-501, Bundang Techni<br />

Park<br />

Sungnam-si, Kyungki-do<br />

463-740 Seoul<br />

Korea<br />

T +82 2 417 9877, 418 1172<br />

F +82 2 416 5553<br />

Mobil +82 10 3999 9720<br />

one4all@one4all.co.kr<br />

KROATIEN<br />

ETT LIGHTING d.o.o. Dobrna<br />

7<br />

3204 Dobrna, Slovenia<br />

T +386 3 7801070<br />

F +386 3 7801078<br />

www.ett-lighting.com<br />

info@ett-lighting.com<br />

LATVIA<br />

Wennerström Ljuskontroll AB<br />

Källdalen<br />

645 91 Strängnäs, Sverige<br />

T +46 152 91000<br />

F +46 152 91078<br />

www.ljuskontroll.com<br />

sales@ljuskontroll.com<br />

LITHUANIA<br />

Wennerström Ljuskontroll AB<br />

Källdalen<br />

645 91 Strängnäs, Sverige<br />

T +46 152 91000<br />

F +46 152 91078<br />

www.ljuskontroll.com<br />

sales@ljuskontroll.com<br />

SPAIN<br />

Tridonic Iberia, S.L.<br />

OFICINA CENTRAL - MADRID<br />

Calle Carpinteros nº 8, 2a<br />

Poligono Industrial Pinares<br />

Llanos<br />

28670 Villaviciosa de Odón<br />

(Madrid)<br />

Spain<br />

Tel: +34 916 162 095<br />

Fax: +34 916 165 695<br />

ventas@tridonic.com<br />

www.tridonic.es<br />

SRI LANKA<br />

GENERAL SALES Co., Ltd.<br />

Senanayake Building,<br />

No. 7, Station Road, Colombo<br />

7, Sri Lanka<br />

T +94 1 574 511<br />

F +94 1 573 673<br />

gescoms@mail.ewisl.net<br />

SOUTH AFRICA<br />

Tridonic SA (Pty) Ltd<br />

53-57 Yaldwyn Road, Hughes<br />

Extension, Jet Park, 1459<br />

P.O. Box 30542, Jet Park, 1469<br />

South Africa<br />

T +27 11 923-9686<br />

F +27 11 923-9684<br />

info@tridonic.co.za<br />

SWEDEN<br />

Wennerström Ljuskontroll AB<br />

Källdalen<br />

645 91 Strängnäs, Sverige<br />

T +46 152 91000<br />

F +46 152 91078<br />

www.ljuskontroll.com<br />

sales@ljuskontroll.com<br />

SWITZERLAND<br />

Tridonic AG Obere Allmeind 2<br />

8755 Ennenda, Schweiz<br />

T +41 55 6454747<br />

F +41 55 6454700<br />

www.tridonic.ch<br />

lumitron@pacific.net.sg<br />

Tridonic S.E.A Pte Ltd<br />

1 Kaki Bukit View<br />

#05-13, Techview<br />

Singapore 415941<br />

T +65 6292 8148<br />

F +65 6293 3700<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 65 / 68 -


&nbsp Ordering information and sources<br />

CZECH REPUBLIC<br />

SCHÄFER & SYKORA spol. s.r.o.<br />

Cihlarska 1000/2<br />

40801 Rumburk<br />

Czech. Republic<br />

T +420 412 354 931<br />

F +420 412 354 945<br />

www.svetlosasa.cz<br />

svetlo@sasa.cz<br />

DENMARK<br />

as Electrotrading<br />

Skiveien 6<br />

Postboks 333<br />

1411 Kolbotn, Norge<br />

T +47 6681 7330<br />

F +47 6681 7333<br />

jan-erik@electrotrading.no<br />

GERMANY<br />

Tridonic Deutschland GmbH<br />

Edisonallee 1<br />

89231 Neu-Ulm, Deutschland<br />

T +49 731 176629-0<br />

F +49 731 176629-15<br />

vertrieb.deutschland@tridonic.com<br />

EASTERN EUROPE<br />

Tridonic<br />

Sales Eastern Europe<br />

Waldfriedenstraße 4a<br />

16792 Zehdenick-Neuhof<br />

Deutschland<br />

T +49 3307 420046<br />

F +49 3307 420047<br />

manfred.heinrich@tridonic.com<br />

ESTONIA<br />

Wennerström Ljuskontroll AB<br />

Källdalen<br />

645 91 Strängnäs, Sverige<br />

T +46 152 91000<br />

F +46 152 91078<br />

www.ljuskontroll.com<br />

FINLAND<br />

Wennerström Ljuskontroll AB<br />

Källdalen<br />

645 91 Strängnäs, Sverige<br />

T +46 152 91000<br />

F +46 152 91078<br />

www.ljuskontroll.com<br />

MALAYSIA<br />

Tridonic (Malaysia) Sdn Bhd<br />

No. 1, Jalan Canggih 9,<br />

Taman Perindustrian<br />

Cemerlang<br />

81800 Ulu Tiram, Johor,<br />

Malaysia<br />

T +65 6292 8148 (Singapore<br />

Office)<br />

F +60 3 91732833<br />

M +60 12 3665281 (Malaysia<br />

contact)<br />

daniel.sy.wong@tridonic.com<br />

MIDDLE EAST<br />

Tridonic (ME) FZE P.O. Box<br />

17972<br />

Jebel Ali Free Zone<br />

Dubai, United Arab Emirates<br />

T +971 4 8833664<br />

F +971 4 8833665<br />

Sales-TAME@tridonic.com<br />

NEW ZEALAND<br />

Tridonic NZ Ltd.<br />

Airport Oaks Mangere<br />

P.O. Box 107044<br />

9 Aintree Ave<br />

Auckland, New Zealand<br />

T +649 256 2310<br />

F +649 256 0109<br />

www.tridonic.com.au<br />

sales@tridonic.co.nz<br />

NETHERLANDS<br />

Elpro b.v. Pascalstraat 3-I<br />

2811 El Reeuwijk,<br />

Netherlands<br />

T +31 182 533633<br />

F +31 182 570414<br />

www.elpro.nl<br />

jan-erik@electrotrading.no<br />

PHILIPPINES<br />

Pacific Lightech Corporation<br />

420, Ortigas Avenue Corner<br />

Xavier Street<br />

Greenhills, San Juan City<br />

Manila<br />

Philippines<br />

T +632 721 0326-66<br />

F +632 721 0361<br />

TAIWAN<br />

BJB Electric Taiwan<br />

Corporation<br />

Tridonic Sole Agent Taiwan<br />

4 / F, No. 108, Chow-Tze<br />

Street,<br />

Nei-hu District (114), Taipei,<br />

Taiwan<br />

T +886 2 2627 7722<br />

F +886 2 2627 1122<br />

bjb@bjb.com.tw<br />

Video Conf.: 886 2 8178<br />

0647~9<br />

THAILAND<br />

DEP Engineering Co. Ltd<br />

107 / 3, Chalermprakiat Rama 9<br />

Road Prawet Sub-District,<br />

Prawet District Bangkok 10250<br />

T +66 (0) 2726 7575<br />

F +66 (0) 2726 7600<br />

TURKEY<br />

Tridonic<br />

Aydınlatma TİC.LTD. ŞTİ.<br />

Kemankeş Mah.,<br />

Necatibey cad. Akçe Sok., Akçe<br />

Han 10<br />

TR-34420 Karaköy / Beyoğlu<br />

Istanbul, Turkey<br />

T +90 212 244 78 05<br />

F +90 212 244 78 06<br />

satis@tridonic.com<br />

ER ELEKTRONIK SAN VE TIC<br />

AS<br />

(for resellers)<br />

YENIYOL SK N:16<br />

80370 KASIMPASA /<br />

ISTANBUL<br />

Turkey<br />

T +90 212 2971941<br />

F +90 212 238 7421<br />

erelektronik@turk.net<br />

USA<br />

TRIDONIC Inc.<br />

4405 International Boulevard<br />

Suite B-113<br />

Norcross, GA 30093, USA<br />

Toll-free: 1-866-TRIDONIC<br />

T +1 770 717 0556<br />

F +1 770 717 7969<br />

www.tridonic.com<br />

sales_usa@tridonic.com<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 66 / 68 -


&nbsp Ordering information and sources<br />

FRANCE<br />

Tridonic France<br />

34 Rue de l'Expansion<br />

67150 Erstein Gare, France<br />

T +33 3 88 59 62 70<br />

F +33 3 88 59 62 75<br />

info@tridonic.fr<br />

GREECE<br />

2 KAPPA Ltd. Stadiou 40<br />

Kalohori<br />

570 09 Thessaloniki, Greece<br />

T +30 2310 775510-13<br />

F +30 2310 775514<br />

www.2kappa.gr<br />

2kappa@pel.forthnet.gr<br />

info@2kappa.gr<br />

GREAT BRITAIN<br />

Tridonic UK Limited<br />

Thomas House Hampshire<br />

International Business Park<br />

Crockford Lane Chineham<br />

Basingstoke<br />

Hampshire RG 24 8LB United<br />

Kingdom<br />

T +44 1256 374300<br />

F +44 1256 374200<br />

enquiries.uk@tridonic.com<br />

...<br />

POLAND<br />

NARVA-Polska Sp. z o.o.<br />

ul. Prosta 69, 00-838<br />

Warszawa<br />

Poland<br />

T +48 22 444 19 60<br />

F +48 22 444 19 61<br />

www.narva.com.pl<br />

biuro@narva.com.pl<br />

PORTUGAL<br />

Tridonic<br />

Sales Office Portugal<br />

Rua do Centro Cultural, 11<br />

1700 - 106 Lisboa, Portugal<br />

T +351 218 438 456<br />

F +351 218 446 613<br />

rui.madrugo@tridonic.com<br />

ROMANIA<br />

Energolux SRL<br />

Str. Taietura Nr. 47 / 11<br />

400221 - Cluj / Napoca<br />

Romania<br />

T +40 264 207500<br />

F +40 264 207555<br />

ebit@energobit.com<br />

UNITED ARAB EMIRATES<br />

Tridonic (ME) FZE P.O. Box<br />

17972<br />

Jebel Ali Free Zone, Dubai<br />

United Arab Emirates<br />

T +971 4 8833664<br />

F +971 4 8833665<br />

Sales-TAME@tridonic.com<br />

VIETNAM<br />

Nien Loi Import Export<br />

Trading Services Co. Ltd<br />

686/72/32 Cach Mang Thang<br />

Tam Street<br />

Ward 11, District 3<br />

Ho Chi Minh City<br />

Vietnam<br />

T +84 8 3993 4314<br />

F +84 8 3993 4315<br />

nienloicorp@vnn.vn<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 67 / 68 -


&nbsp Ordering information and sources<br />

Additional information<br />

Go to www.tridonic.com to find your personal contact at Tridonic.<br />

Further information and ordering data:<br />

TALEXX catalogue at www.tridonic.com menue Services > Literature > Catalogue<br />

Data sheets at www.tridonic.com menue Technical data > Data sheets<br />

Certificates at www.tridonic.com menue Technical data > Certificates<br />

Technical Design-in Guide <strong>TALEXXengine</strong> <strong>STARK</strong> <strong>SLE</strong> <strong>GEN2</strong> | 12-2012 | en - 68 / 68 -