26.12.2012 Views

Development of a Cold Gas Propulsion System for the ... - SSL - MIT

Development of a Cold Gas Propulsion System for the ... - SSL - MIT

Development of a Cold Gas Propulsion System for the ... - SSL - MIT

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>the</strong> solenoid valve, and a pressure transducer was placed on one arm <strong>of</strong> each <strong>of</strong> <strong>the</strong> crosses. A<br />

<strong>the</strong>rmocouple was placed opposite each pressure transducer, with <strong>the</strong> goal <strong>of</strong> collecting temperature<br />

data to be used in validating <strong>the</strong> MATLAB model.<br />

The entire thruster assembly – crosses, solenoid valve, and nozzle – was clamped onto a plat<strong>for</strong>m on<br />

wheel bearings. One end <strong>of</strong> <strong>the</strong> plat<strong>for</strong>m was attached to a single-axis load cell, which in turn was bolted<br />

onto a heavy stationary frame. Thus, <strong>the</strong> plat<strong>for</strong>m could not actually roll, but <strong>the</strong> wheel bearings<br />

minimized <strong>the</strong> lateral <strong>for</strong>ces opposing <strong>the</strong> thruster. To fur<strong>the</strong>r minimize external <strong>for</strong>ces, <strong>the</strong> thruster was<br />

fed nitrogen through a flexible hose ra<strong>the</strong>r than a fixed, rigid line. The plat<strong>for</strong>m and thruster assembly<br />

are pictured in Figure 5-2 below.<br />

Figure 5-2. Thruster and instrumentation <strong>for</strong> single-stream characterization tests.<br />

All <strong>of</strong> <strong>the</strong> sensors used in <strong>the</strong> single-stream tests output signals as analog voltages. These signals were<br />

collected with a National Instruments (NI) USB-6216 data acquisition device, or DAQ, which was also<br />

used to actuate <strong>the</strong> solenoid valve via a relay. 6<br />

The DAQ was connected by USB cable to a laptop running<br />

NI’s LabVIEW s<strong>of</strong>tware, where sensor signals were converted to data in <strong>the</strong> units <strong>of</strong> <strong>the</strong> property being<br />

measured be<strong>for</strong>e being logged, and control signals were input. At first, opening and closing <strong>the</strong> valve<br />

6 The digital output used to control <strong>the</strong> solenoid valve and <strong>the</strong> analog input used to collect <strong>the</strong> sensor signals did<br />

not run on <strong>the</strong> same clock in <strong>the</strong> DAQ, so an extra wire was run from <strong>the</strong> digital output to a spare analog input pin<br />

in order to have a record <strong>of</strong> <strong>the</strong> command signal with <strong>the</strong> same timestamp as <strong>the</strong> rest <strong>of</strong> <strong>the</strong> sensors.<br />

75

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!