5.3 Connecting pipes<br />

5.4 Filling with lubricating oil<br />

NOTICE<br />

Installation<br />

Material damage resulting from the forces and<br />

torques of the pipes on the unit being too high<br />

Only screw pipes in by hand..<br />

The pumping capacity of the vacuum pump<br />

is reduced if the suction pipe is too narrow<br />

and/or too long.<br />

The air vent (Fig. 1/B) must not be closed or<br />

restricted.<br />

Counter pressures on the outlet side are only<br />

permissible up to + 0.1 bars.<br />

Prevent liquids accumulating in the exhaust<br />

line<br />

a) The vacuum connection at (Fig. 1/A).<br />

b) The air handled can be exhausted into the atmosphere<br />

through the silencer (Fig. 1/B).<br />

a) Fill the lubricating oil (for suitable types see the<br />

„Maintenance“ section) via the oil fi lling point<br />

(Fig. 1/H) up to the upper edge of the sight glass<br />

(Fig. 1/I).<br />

b) Close the oil fi lling point.<br />

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH |<br />