5.3 Connecting pipes<br />
5.4 Filling with lubricating oil<br />
NOTICE<br />
Installation<br />
Material damage resulting from the forces and<br />
torques of the pipes on the unit being too high<br />
Only screw pipes in by hand..<br />
The pumping capacity of the vacuum pump<br />
is reduced if the suction pipe is too narrow<br />
and/or too long.<br />
The air vent (Fig. 1/B) must not be closed or<br />
restricted.<br />
Counter pressures on the outlet side are only<br />
permissible up to + 0.1 bars.<br />
Prevent liquids accumulating in the exhaust<br />
line<br />
a) The vacuum connection at (Fig. 1/A).<br />
b) The air handled can be exhausted into the atmosphere<br />
through the silencer (Fig. 1/B).<br />
a) Fill the lubricating oil (for suitable types see the<br />
„Maintenance“ section) via the oil fi lling point<br />
(Fig. 1/H) up to the upper edge of the sight glass<br />
(Fig. 1/I).<br />
b) Close the oil fi lling point.<br />
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH |<br />