- Page 1: ASME Code Case on Use of Alternativ
- Page 5 and 6: Charlie ChongB31 CASE 181-1CASES OF
- Page 7 and 8: ASME B31.3344.6 Ultrasonic Examinat
- Page 9 and 10: 344.6.2 Acceptance Criteria. A line
- Page 11 and 12: (c) The ultrasonic examination shal
- Page 13 and 14: Charlie ChongThe qualification bloc
- Page 15 and 16: T-434.1.2 Material.(a) Similar Meta
- Page 17 and 18: Flaw size shall be no larger than t
- Page 19 and 20: Charlie ChongGENERAL NOTES:(a)t = t
- Page 21 and 22: Charlie ChongTABLE 2FLAW ACCEPTANCE
- Page 23 and 24: Charlie Chong(d) The ultrasonic exa
- Page 25 and 26: Charlie Chong(e) Data is recorded i
- Page 27 and 28: (i) Data analysis and acceptance cr
- Page 29 and 30: Charlie Chong(2) Geometric. Ultraso
- Page 31 and 32: Charlie Chong(c) Alternatively, oth
- Page 33 and 34: (b) Multiple Flaws(1) Discontinuous
- Page 35 and 36: Charlie ChongFigure 3
- Page 37 and 38: Charlie ChongFigure 5
- Page 39 and 40: Charlie Chong(d) With the owner’s
- Page 41 and 42: ASME B31.1- 346 RECORDS346.2 Respon
- Page 43 and 44: Charlie ChongB31 Case 181-2Original
- Page 45 and 46: 344.6.2 Acceptance Criteria. A line
- Page 47 and 48: Charlie Chong4) Examinationa)The in
- Page 49 and 50: Charlie Chong5) Data RecordingData
- Page 51 and 52: Charlie ChongStored valves shall be
- Page 53 and 54:
Charlie ChongStored valves shall be
- Page 55 and 56:
Charlie ChongStored valves shall be
- Page 57 and 58:
Charlie ChongStored valves shall be
- Page 59 and 60:
Charlie ChongStored valves shall be
- Page 61 and 62:
Charlie ChongStored valves shall be
- Page 63 and 64:
Charlie ChongStored valves shall be
- Page 65 and 66:
Charlie ChongStored valves shall be
- Page 67 and 68:
Charlie ChongStored valves shall be
- Page 69 and 70:
Charlie ChongStored valves shall be
- Page 71 and 72:
Charlie ChongStored valves shall be
- Page 73 and 74:
Charlie ChongStored valves shall be
- Page 75 and 76:
Charlie ChongStored valves shall be
- Page 77 and 78:
Charlie ChongStored valves shall be
- Page 79 and 80:
Charlie ChongStored valves shall be
- Page 81 and 82:
Charlie ChongStored valves shall be
- Page 83 and 84:
Charlie ChongStored valves shall be
- Page 85 and 86:
Charlie ChongStored valves shall be
- Page 87 and 88:
Charlie ChongStored valves shall be
- Page 89 and 90:
Charlie ChongStored valves shall be
- Page 91 and 92:
Charlie ChongStored valves shall be
- Page 93 and 94:
Charlie ChongStored valves shall be
- Page 95 and 96:
Charlie ChongStored valves shall be
- Page 97 and 98:
Charlie ChongStored valves shall be
- Page 99 and 100:
Charlie ChongStored valves shall be
- Page 101 and 102:
Charlie ChongStored valves shall be
- Page 103 and 104:
Charlie ChongStored valves shall be
- Page 105 and 106:
Charlie ChongStored valves shall be
- Page 107 and 108:
Charlie ChongStored valves shall be
- Page 109 and 110:
Charlie ChongStored valves shall be
- Page 111 and 112:
Charlie ChongStored valves shall be
- Page 113 and 114:
Charlie ChongStored valves shall be
- Page 115 and 116:
Charlie ChongStored valves shall be
- Page 117 and 118:
Charlie ChongStored valves shall be
- Page 119 and 120:
Charlie ChongStored valves shall be
- Page 121 and 122:
Charlie ChongStored valves shall be
- Page 123 and 124:
Charlie ChongStored valves shall be
- Page 125 and 126:
Charlie ChongStored valves shall be
- Page 127 and 128:
Charlie ChongStored valves shall be
- Page 129 and 130:
Charlie ChongStored valves shall be
- Page 131 and 132:
Charlie ChongStored valves shall be
- Page 133 and 134:
Charlie ChongStored valves shall be
- Page 135 and 136:
Charlie ChongStored valves shall be
- Page 137 and 138:
Charlie ChongStored valves shall be
- Page 139 and 140:
Charlie ChongStored valves shall be
- Page 141 and 142:
Charlie ChongStored valves shall be
- Page 143 and 144:
(b) Category M Fluid Service: a flu
- Page 145 and 146:
Charlie ChongStored valves shall be
- Page 147 and 148:
1.0 Valve BodyThe valve body, somet
- Page 149 and 150:
5 Valve Certification and Retesting
- Page 152 and 153:
Charlie Chong/ Fion Zhang
- Page 154 and 155:
Charlie Chong/ Fion Zhang