TROUBLE SHOOTING<br />
Fault: Volume Control at Master does not adjust music level on a 6-wire system.<br />
Fix: The conversion to 6-wire at the Master is achieved not by programming, but by fitting<br />
wire links between the COM1 to MUS1 and COM2 to MUS2 terminals. Ensure Master is<br />
programmed to 8-wire.<br />
Fault: On a 6-wire system Music mutes when the talk button is pressed but returns as<br />
soon as the talk button is released.<br />
Fix: For 6-wire systems, music is transmitted on the same cables as communication<br />
therefore music must be muted throughout the system whenever communication takes<br />
place. To achieve this, ensure the jumper is fitted to both the link pins labelled L1 on the<br />
Master Audio Interface PCB or the Auxiliary Input Jack for Room Station only systems.<br />
Fault: House and door talk functions work correctly but no communication using numerical<br />
private dialling.<br />
Fix: Ensure Room Stations have been coded correctly and all stations are set to either<br />
single digit or double digit dialling format.<br />
Fault: Music and monitoring is not being received at certain Room Stations although<br />
communication is being received okay.<br />
Fix: Ensure that all stations are correctly programmed to either 8-wire or 6-wire<br />
(Master must be programmed to 8-wire in all cases).<br />
Fault: No communication or chimes, on a "Room Station Only" system.<br />
Fix: - Ensure load resistor is fitted to system.<br />
- Make sure the load resistor is not shorting against the speaker when the fascia is<br />
attached to the Room Station.<br />
- At all stations, ensure the VLC and TC wires are in the correct terminals and have<br />
not been reversed.<br />
- At all stations, ensure that there are no exposed wires at any terminals.<br />
Fault: No communication or chimes on a "Master" system.<br />
Fix: - At all stations, ensure the VLC and TC wires are in the correct terminals and have<br />
not been reversed.<br />
- At all stations, ensure that there are no exposed wires at any terminals.<br />