TROUBLE SHOOTING<br />

Fault: Volume Control at Master does not adjust music level on a 6-wire system.<br />

Fix: The conversion to 6-wire at the Master is achieved not by programming, but by fitting<br />

wire links between the COM1 to MUS1 and COM2 to MUS2 terminals. Ensure Master is<br />

programmed to 8-wire.<br />

Fault: On a 6-wire system Music mutes when the talk button is pressed but returns as<br />

soon as the talk button is released.<br />

Fix: For 6-wire systems, music is transmitted on the same cables as communication<br />

therefore music must be muted throughout the system whenever communication takes<br />

place. To achieve this, ensure the jumper is fitted to both the link pins labelled L1 on the<br />

Master Audio Interface PCB or the Auxiliary Input Jack for Room Station only systems.<br />

Fault: House and door talk functions work correctly but no communication using numerical<br />

private dialling.<br />

Fix: Ensure Room Stations have been coded correctly and all stations are set to either<br />

single digit or double digit dialling format.<br />

Fault: Music and monitoring is not being received at certain Room Stations although<br />

communication is being received okay.<br />

Fix: Ensure that all stations are correctly programmed to either 8-wire or 6-wire<br />

(Master must be programmed to 8-wire in all cases).<br />

Fault: No communication or chimes, on a "Room Station Only" system.<br />

Fix: - Ensure load resistor is fitted to system.<br />

- Make sure the load resistor is not shorting against the speaker when the fascia is<br />

attached to the Room Station.<br />

- At all stations, ensure the VLC and TC wires are in the correct terminals and have<br />

not been reversed.<br />

- At all stations, ensure that there are no exposed wires at any terminals.<br />

Fault: No communication or chimes on a "Master" system.<br />

Fix: - At all stations, ensure the VLC and TC wires are in the correct terminals and have<br />

not been reversed.<br />

- At all stations, ensure that there are no exposed wires at any terminals.<br />