CHECKLIST FOR 6-WIRE INSTALLATION<br />
All the information required for a 6-wire installation is contained in the various sections of<br />
this manual.<br />
Below is a summary of items that need to be addressed for 6-wire operation.<br />
1. Fit wire link between COM1 and MUS1 (at Master only).<br />
2. Fit wire link between COM2 and MUS2 (at Master only).<br />
3. Fit shunt across jumper “L1” on Audio PCB in Master labelled “AUXILIARY INPUT<br />
BOARD”.<br />
4. Leave Master programmed to “8-wire”.<br />
5. Program each Room Station to “6-wire” as follows:<br />
- Enter Program Mode by pressing the “PRIV” and “MON” buttons at the same time.<br />
- Toggle between 6-wire and 8-wire modes by pressing the “HOUSE” button.<br />
- Green L.E.D. on indicates 8-wire mode.<br />
- Green L.E.D. off indicates 6-wire mode.<br />
- Press “CAN” (CANCEL) button to exit program mode and lock in selection.<br />
6. Wire Auxiliary Input Type B (if fitted) according to 6-wire instructions and ensure<br />
shunt is fitted so as to bridge Link “L1”.<br />