CHANGING THE CHIME<br />
The chime melody can be changed to any one of nine options by means of the two<br />
programming switches (SEL and PROG) situated on the Door Station circuit board as<br />
indicated below.<br />
POS<br />
NEG<br />
COM1<br />
COM2<br />
U5<br />
VR3<br />
TC<br />
VLC<br />
SHLD<br />
VR1 SEL<br />
VR2<br />
CH<br />
PROG<br />
PROCEDURE:<br />
Press the PPROGRAM button (PROG) – The red L.E.D. illuminates and the current chime<br />
plays.<br />
Press the SELECT button (SEL) – The next chime option plays.<br />
Repeatedly press the SELECT button until the desired melody is heard.<br />
Press the PROGRAM button to lock in selection – The red L.E.D. flashes.<br />
Press the PROGRAM button again to exit PROGRAM mode – The red L.E.D. extinguishes.<br />
Pressing the SELECT button, after all the nine chime options have been sampled will cycle<br />
back to the first chime option.<br />