26.12.2012 Views

Installation

Installation

Installation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

WIRING VOLTAGE OUTPUTS<br />

The Lock output (LK) and Chime Voltage output (CH) will provide 12 Volt DC @ 50mA<br />

which can be used to power up relays which in turn will switch voltage to the device being<br />

used.<br />

WARNING<br />

Using these outputs to drive a load, with a resistance of less than 240 ohm, will damage<br />

the output transistors.<br />

Check coil resistance of relays to be used with a multimeter.<br />

LOCK OUTPUT<br />

LK<br />

+<br />

CH<br />

RELAY 12V DC *<br />

RELAY 12V DC *<br />

N.C.<br />

COM<br />

N.O.<br />

N.C.<br />

COM<br />

N.O.<br />

* RELAY COIL RESISTANCE SHOULD NOT BE LESS THAN 240 OHM<br />

The LK terminal provides an output voltage (to activate an automatic gate or release a<br />

door strike) whenever an “8” button is pressed at the Master or any Room Station.<br />

To use this output, no additional wiring is required between the Master, Room Stations and<br />

the Door Station, except for the cable required to deliver power from the power source, via<br />

the lock relay contacts, to the lock - see section "<strong>Installation</strong> of VF103 Door Stations - Lock<br />

Output".<br />

If this feature is to be used, number “8” should be avoided when programming Room<br />

Stations for private dialling.<br />