INSTALLATION OF POWER SUPPLY<br />

A regulated 13.8V dc power supply is required to power the system.<br />

For systems using a Master, it is imperative that a LINEAR regulated supply be used, as<br />

SWITCH MODE regulated supplies will cause interference with AM radio reception.<br />

NOTE: - Since some linear supplies also generate interference, it is recommended that<br />

only power supplies recommended by a Valet Dealer be used.<br />

- See sections "LOCATION OF EQUIPMENT" and "WHAT CABLE TO USE" for<br />

important details on power supply location and cabling.<br />

POWER SUPPLY CURRENT RATING<br />

It is important to use a power supply with a current rating sufficient for the size of the system.<br />

The power supply current rating is determined by the peak current requirement of the system<br />

as a whole and can be calculated by adding the peak current requirement of each of the<br />

stations making up the system.<br />

The table on the right shows the current<br />

consumption for each of the individual<br />

components.<br />

The following calculation example is for<br />

a system made up of a Music Master,<br />

6 Rooms and 1 Door.<br />

1 x 0.45A for the Master = 0.45A<br />

6 x 0.15A for six rooms = 0.9A<br />

1 x 0.15A for the door = 0.15A<br />

Total = 0.45A + 0.9A + 0.15A = 1.5A<br />

System One Item Current<br />

Master Station – Music 0.45A<br />

Master Station – Secure 0.5A<br />

Room Station 0.15A<br />

Door Station 0.15A<br />

Auxiliary Input Jack 0.1A<br />

External Siren 1A<br />

External Strobe 0.1A<br />

The above system requires a 13.8Vdc linear regulated supply rated at 1.5 amp or better.<br />

CONNECTION TO A MASTER SYSTEM<br />

For a system fitted with a Master Station, the power supply is to be connected to the<br />

Master Station.<br />

The Master Station has a dedicated pair of terminals labelled "13.8V I-P" on the<br />

termination PCB for the connection of the power supply.<br />

Because a DC power supply is used, it is important that the positive lead of the power<br />

supply connects to the POS terminal and the negative lead of the power supply connects<br />

to the NEG terminal.<br />