Wiring the CH Output<br />

The Chime Voltage Output terminal (CH) will provide 12 Volt DC @ 50mA which can be<br />

used to power up a relay, which in turn will switch voltage to the device being used.<br />

WARNING<br />

Using this output to drive a load with a resistance of less than 240 ohm will damage the<br />

output transistor.<br />

Check relay coil resistance with a multimeter.<br />

POS<br />

NEG<br />

COM1<br />

COM2<br />

TC<br />

VLC<br />

SHIELD<br />

CH<br />

Resistance of relay<br />

coil should be 240<br />

ohm or greater<br />

V+ and V- can be taken from POS and NEG<br />

of the door station for low current applications<br />

(500mA or less).<br />

A separate power source is recommended for<br />

higher current applications.<br />

12V RELAY<br />

V-<br />

N-C<br />

COM<br />

N-O<br />

V+<br />

OUTPUT<br />