Installation
Installation
Installation
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Wiring the CH Output<br />
The Chime Voltage Output terminal (CH) will provide 12 Volt DC @ 50mA which can be<br />
used to power up a relay, which in turn will switch voltage to the device being used.<br />
WARNING<br />
Using this output to drive a load with a resistance of less than 240 ohm will damage the<br />
output transistor.<br />
Check relay coil resistance with a multimeter.<br />
POS<br />
NEG<br />
COM1<br />
COM2<br />
TC<br />
VLC<br />
SHIELD<br />
CH<br />
Resistance of relay<br />
coil should be 240<br />
ohm or greater<br />
V+ and V- can be taken from POS and NEG<br />
of the door station for low current applications<br />
(500mA or less).<br />
A separate power source is recommended for<br />
higher current applications.<br />
12V RELAY<br />
V-<br />
N-C<br />
COM<br />
N-O<br />
V+<br />
OUTPUT<br />