INSTALLATION OF VF102 DOOR STATIONS<br />
These stations are best located adjacent to the front door or at the front gate at a<br />
suggested height of 1400 millimetres and will require either a surface mount wall box or a<br />
flush mount wall box depending on the mounting surface and personal preference.<br />
Any Station exposed to the weather will require the fitting of a weatherproof cover.<br />
Where stations are to be installed in solid brick or concrete columns at a front gate, it is<br />
required that the cable be run in conduit from the station to below ground level and back to<br />
the house.<br />
When using 8-wire cable to connect to the Door Station, do not connect the two spare<br />
wires to the MUS1 and MUS2 terminals at the Master Station (or Room Station) end of the<br />
cable.<br />
The two spare wires from an 8-wire cable may be wired in parallel to the POS and NEG<br />
wires to the gate station, to double the maximum cable distance to a length of 200 metres.<br />
Where a Door Station is part of a wiring loop, the Door Station should generally be the last<br />
station on the loop.<br />
CABLE TERMINATION FOR VF 102 DOOR STATION<br />
Using Valet Cable<br />
RED<br />
BLACK<br />
WHITE<br />
BLUE<br />
Green and Orange to be taped back<br />
at this end and also at other end.<br />
POS<br />
NEG<br />
COM1<br />
COM2<br />
U5<br />
VR1<br />
VR2<br />
GREEN<br />
ORANGE<br />
VR3<br />
TC<br />
VLC<br />
SHLD<br />
CH<br />
SEL<br />
PROG<br />
NOTE: RESISTANCE OF RELAY COIL<br />
SHOULD BE 240 OHM OR GREATER<br />
SHIELDED RED<br />
SHIELDED WHITE<br />
OUTER SHIELD<br />
12V<br />
RELAY<br />
COIL N-O<br />
NOTE: Outer shield should<br />
be insulated.<br />
POS<br />
NEG<br />
OPTIONAL<br />
*<br />
ADDITION<br />
Mech<br />
Chime<br />
31