INSTALLATION OF VF103 DOOR STATIONS<br />
These stations are best located adjacent to the front door or at the front gate at a<br />
suggested height of 1400 millimetres and may require a wall box depending upon the<br />
surface to which they are to be affixed.<br />
Any station exposed to the weather will require the fitting of a weatherproof cover.<br />
Where stations are to be installed in solid brick or concrete columns at a front gate, it is<br />
required that the cable be run in conduit from the station to below ground level and back to<br />
the house.<br />
When using 8-wire cable to connect to the Door Station, do not connect the spare two wires<br />
to the MUS1/MUS2 terminals at the Master Station (or Room Station) end of the cable.<br />
The two spare wires from an 8-wire cable may be wired in parallel to the POS and NEG<br />
wires to the gate station, to double the maximum cable distance to a length of 200 metres.<br />
Where a Door Station is part of a wiring loop, the Door Station should generally be the last<br />
station on the loop.<br />
BRICK<br />
REMOVED<br />
INSERT WALL BOX<br />
INTO OPENING<br />
WOOD FIXING SCREW (26mm)<br />
DOOR STATION – BRICK WALL<br />
WALL BOX<br />
BACK HOUSING<br />
WOOD FIXING SCREW (26mm)<br />
FASCIA<br />