BLOCK DIAGRAMS FOR ROOM STATION ONLY SYSTEMS<br />
Star Wired System<br />
ROOM 1<br />
ROOM 2<br />
Power Supply<br />
Input Jack<br />
Type B<br />
ROOM 3 DOOR<br />
ROOM 4 ROOM 5<br />
Power Supply<br />
ROOM 6<br />
Note: The maximum length (in metres) of any individual wiring run = 100 divided by the number of stations on the run.<br />
i.e. The maximum length for the cable run connecting Rooms 1, 4,5 & 6, is<br />
100m ÷ 3 room stations = 33 metres in total.<br />
(Room 1 is not used in the calculation because it is the station to which the power supply is connected)<br />
Loop Wired System<br />
Plug Pack<br />
Input Jack<br />
Type B<br />
Plug Pack<br />
ROOM 1 ROOM 2 ROOM 3 DOOR<br />
Note: The maximum length (in metres) of any individual wiring run = 100 divided by the number of stations on the run.<br />
i.e. The maximum length for the cable run connecting the Door station and Rooms 1,2 & 3, is<br />
100m ÷ 3 stations = 33 metres in total.<br />
(Room 1 is not used in the calculation because it is the station to which the power supply is connected)<br />
A Load Resistor is required on Room Station Only systems. In the examples<br />
above, the Load Resistor should be fitted across the VLC and NEG terminals<br />
of Room 1 (the Room Station to which the power supply is connected).<br />
Relay<br />
Relay<br />
Lock<br />
Lock<br />