MAXIMUM LENGTH FOR CABLE RUNS<br />

The system may be "star wired" from a central point or "loop wired" however the number of<br />

stations on a loop wired run governs the overall length of the run.<br />

The table below shows the relationship between the length of a cable run and the number<br />

of stations permitted on the run.<br />

A cable run is considered to begin at the station to which the power supply is connected.<br />

Number of stations for a given cable run length<br />

Cable run length No. of stations permitted<br />

51 to100 metres 1 station<br />

34 to 50 metres 2 stations<br />

26 to 33 metres 3 stations<br />

1 to 25 metres 4 stations<br />

These maximum distances can be doubled where required by running a “figure 8” cable<br />

(14 x 0.2 mm) in parallel with the POS & NEG wires.<br />

It is vitally important that the POS and NEG wires are balanced in terms of the type of wire<br />

and the number of wires used - i.e. if a Fig 8 wire and a Valet wire are used for POS, a Fig<br />

8 wire and a Valet wire should also be used for NEG.<br />

7