166 Chapter Eight

Figure 8-46. GM CS AC generator (alternator) regulator

circuit. (Delphi Automotive Systems)

Figure 8-45. When AC generator (alternator) output

voltage reaches a maximum safe level, no current is

allowed in the rotor winding. (Delphi Automotive Systems)

no test hole to ground the regulator for full-field

testing. The regulator cannot be tested with an

ohmmeter; a special tester is required.

Motorcraft

At one time, Motorcraft AC generators used both

remote-mounted and integral solid-state regulators.

Motorcraft regulator terminals are designated

as follows:

• A or A connects the battery to the field

relay contacts.

• S connects the AC generator output to the

field relay coil.

• F connects the field coil to the regulator

transistors.

• I connects the ignition switch to the field

relay and regulator contacts (only on vehicles

with a warning lamp).

Ford began using a remote-mounted, fully solidstate

regulator on its intermediate and large models

in 1978. The functions of the I, A, 8, and F

terminals are identical to those of the transistorized

regulator. On systems with an ammeter,

the regulator is color coded blue or gray, and the

T terminal is not used. On warning lamp systems,

the regulator is black, and all terminals can be

used. The two models are not interchangeable,

and cannot be substituted for the earlier solidstate

unit with a relay or for an electromagnetic

regulator. However, Ford does provide red or

clear service replacement solid-state regulators,

which can be used with both systems.

The Motorcraft integral alternator/regulator

(JAR) introduced in 1985 uses an IC regulator,

which is also mounted on the outside of the rear

housing. This regulator differs from others because

it contains a circuit indicating when the battery is

being overcharged. It turns on the charge indicator

lamp if terminal A voltage is too high or too low, or

if the terminal 8 voltage signal is abnormal.

DaimlerChrysler

The DaimlerChrysler solid-state regulator depends

on a remotely mounted field relay to open and

close the isolated field or the A-circuit AC generator

field. The relay closes the circuit only when the

ignition switch is turned on. The voltage regulator

(Figure 8-47) contains two transistors that are

turned on and off by a Zener diode. The Zener

diode reacts to system voltage to start and stop field