<strong>TT</strong>-<strong>3000E</strong> <strong>mini</strong>-C <strong>GMDSS</strong> <strong>User</strong> <strong>Manual</strong><br />

11 Geoidal separation.<br />

13 Age of differential GPS data.<br />

ZDA 5 Local zone hours.<br />

There is approximately a one second interval between<br />

two equal sentences. The position is updated every 30<br />

seconds.<br />

NMEA-out is enabled/disabled from “Secondary serial<br />

port…” in the Options menu. When enabled, <strong>TT</strong>-<strong>3000E</strong><br />

will immediately start sending out sentences at the<br />

secondary serial port. The port (COM1/COM2) used can<br />

be changed in the serial ports settings. Refer to 5.7.4<br />

Configuring the Serial Port.<br />

5.5.37 LINK TEST<br />

The Link Test checks if your equipment meets the<br />

specifications set out by Inmarsat. As previously described,<br />

a Link Test will be carried out when performing a login for<br />

the first time. The test is then regarded <strong>as</strong> a commissioning<br />

procedure. You may do a Link Test at any time if you want<br />

to check your system again.<br />

1. Choose Options, Link test (Alt, O, I) to have the<br />

Link Test window displayed. If a test h<strong>as</strong> been<br />

carried out, the results will be shown. Each item<br />

will have the verdict OK or FAIL. If no test h<strong>as</strong><br />

been done with this unit, no results will be<br />

available.<br />