25.12.2012 Views

Front Matter - The Journal of Bone & Joint Surgery

Front Matter - The Journal of Bone & Joint Surgery

Front Matter - The Journal of Bone & Joint Surgery

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

it 4,<br />

L<br />

/<br />

JEWETT NAILS<br />

NO. 381N JEWETT HIP NAIL<br />

For trochanteric, intratrochanteric and subtrochanteric fractures <strong>of</strong> the femur.<br />

Plate prevents extrusion or migration <strong>of</strong> the Smith-Petersen nail portion.<br />

Regular stock sizes <strong>of</strong> Jewett hip nails are cannulated, angle <strong>of</strong> l35, with nail<br />

and plate lengths sx follows:<br />

NAIL LENGTHS<br />

2/2”, 23/4, 3” 3#{188}”, 3/2”, $12.50 each<br />

4#{188}”, 4/2”, 43/4”, 5 13.50 each<br />

51/4”, 51/2”, 5/4”, 6 14.50 each<br />

Each <strong>of</strong> the above nail sizes furnished in the following plate lengths: 2”, 3”, 4”,<br />

5”, 6” (For plate lengths longer than 6”, add $1.25 per inch).<br />

All Richards Jewett Nails are solid forged <strong>of</strong> one piece SMO Stainless<br />

Steel. <strong>The</strong> plate ends are rounded to eliminate abrupt protrusion <strong>of</strong> the<br />

plate from the bone. <strong>The</strong> underside <strong>of</strong> the plate is curved completely to<br />

the apex <strong>of</strong> the angle, making it snug.fitting to the bone.<br />

<strong>The</strong> angle may be changed from standard by using the No. 414 Jewett<br />

Benders. However, if more than lO change is desired, we recommend<br />

that we make the nail special, properly forming the angle in our hot<br />

forging process.<br />

NO. 381 P JEWETT SUPRACONDYLAR NAIL<br />

Designed to snugly fit the contour <strong>of</strong> the condyles and shaft <strong>of</strong> the femur.<br />

Tri-f’anged nail gives firm support.<br />

After a guide wire is passed through the condyles, a /2” D. reamer is placed<br />

over the guide wire to ream out a small portion <strong>of</strong> the lateral cortex to provide<br />

close coaptation <strong>of</strong> the nail. <strong>The</strong> nail is then placed over the guide wire and<br />

driven to just pass through the cortex <strong>of</strong> the medial condyle.<br />

A regular Jewetf or Smith-Petersen driver may be used. Cannulated for<br />

3/32” guide pins, the nail may also be used in conjunction with a tibia bolt and<br />

washer +o hold fragments.<br />

Unless otherwise specified, plate length <strong>of</strong> 6” furnished, with nail<br />

lengths as follows:<br />

2”, 2#{188}”, 2’/2”, 23/4”, 3” 3#{188}”,3’/2”, 33/4”, 4 $17.50<br />

NO. 3815 JEWETT SHOULDER NAIL<br />

Indicated for fractures <strong>of</strong> the upper end <strong>of</strong> the humerus, mainly in the surgical<br />

neck area, or ix fractures involving both the anatomical and the surgical neck<br />

in some instances,<br />

Also adaptable for rotation osteotomies in the upper end <strong>of</strong> the femur in<br />

the young patient. <strong>The</strong> nail is not long enough to go into the epiphysis<br />

<strong>of</strong> the head <strong>of</strong> the femur yet is long enough to give stability with the<br />

use <strong>of</strong> a plaster spica. Nail is removed following complete healing<br />

<strong>of</strong> the bone.<br />

MANU.FATURING:O,,MEMpHi5,TENN.<br />

Reduced in all dimensions from regular Jeweft Nail. Non-cannu.<br />

lated. Plate length 2”; nail lengths as follows:<br />

I”, #{188}”, ‘/2”, 13/4 $12.50 each<br />

In answering advertisements, 1Se mention Time <strong>Journal</strong> <strong>of</strong> <strong>Bone</strong> and <strong>Joint</strong> <strong>Surgery</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!