Front Matter - The Journal of Bone & Joint Surgery
Front Matter - The Journal of Bone & Joint Surgery
Front Matter - The Journal of Bone & Joint Surgery
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
it 4,<br />
L<br />
/<br />
JEWETT NAILS<br />
NO. 381N JEWETT HIP NAIL<br />
For trochanteric, intratrochanteric and subtrochanteric fractures <strong>of</strong> the femur.<br />
Plate prevents extrusion or migration <strong>of</strong> the Smith-Petersen nail portion.<br />
Regular stock sizes <strong>of</strong> Jewett hip nails are cannulated, angle <strong>of</strong> l35, with nail<br />
and plate lengths sx follows:<br />
NAIL LENGTHS<br />
2/2”, 23/4, 3” 3#{188}”, 3/2”, $12.50 each<br />
4#{188}”, 4/2”, 43/4”, 5 13.50 each<br />
51/4”, 51/2”, 5/4”, 6 14.50 each<br />
Each <strong>of</strong> the above nail sizes furnished in the following plate lengths: 2”, 3”, 4”,<br />
5”, 6” (For plate lengths longer than 6”, add $1.25 per inch).<br />
All Richards Jewett Nails are solid forged <strong>of</strong> one piece SMO Stainless<br />
Steel. <strong>The</strong> plate ends are rounded to eliminate abrupt protrusion <strong>of</strong> the<br />
plate from the bone. <strong>The</strong> underside <strong>of</strong> the plate is curved completely to<br />
the apex <strong>of</strong> the angle, making it snug.fitting to the bone.<br />
<strong>The</strong> angle may be changed from standard by using the No. 414 Jewett<br />
Benders. However, if more than lO change is desired, we recommend<br />
that we make the nail special, properly forming the angle in our hot<br />
forging process.<br />
NO. 381 P JEWETT SUPRACONDYLAR NAIL<br />
Designed to snugly fit the contour <strong>of</strong> the condyles and shaft <strong>of</strong> the femur.<br />
Tri-f’anged nail gives firm support.<br />
After a guide wire is passed through the condyles, a /2” D. reamer is placed<br />
over the guide wire to ream out a small portion <strong>of</strong> the lateral cortex to provide<br />
close coaptation <strong>of</strong> the nail. <strong>The</strong> nail is then placed over the guide wire and<br />
driven to just pass through the cortex <strong>of</strong> the medial condyle.<br />
A regular Jewetf or Smith-Petersen driver may be used. Cannulated for<br />
3/32” guide pins, the nail may also be used in conjunction with a tibia bolt and<br />
washer +o hold fragments.<br />
Unless otherwise specified, plate length <strong>of</strong> 6” furnished, with nail<br />
lengths as follows:<br />
2”, 2#{188}”, 2’/2”, 23/4”, 3” 3#{188}”,3’/2”, 33/4”, 4 $17.50<br />
NO. 3815 JEWETT SHOULDER NAIL<br />
Indicated for fractures <strong>of</strong> the upper end <strong>of</strong> the humerus, mainly in the surgical<br />
neck area, or ix fractures involving both the anatomical and the surgical neck<br />
in some instances,<br />
Also adaptable for rotation osteotomies in the upper end <strong>of</strong> the femur in<br />
the young patient. <strong>The</strong> nail is not long enough to go into the epiphysis<br />
<strong>of</strong> the head <strong>of</strong> the femur yet is long enough to give stability with the<br />
use <strong>of</strong> a plaster spica. Nail is removed following complete healing<br />
<strong>of</strong> the bone.<br />
MANU.FATURING:O,,MEMpHi5,TENN.<br />
Reduced in all dimensions from regular Jeweft Nail. Non-cannu.<br />
lated. Plate length 2”; nail lengths as follows:<br />
I”, #{188}”, ‘/2”, 13/4 $12.50 each<br />
In answering advertisements, 1Se mention Time <strong>Journal</strong> <strong>of</strong> <strong>Bone</strong> and <strong>Joint</strong> <strong>Surgery</strong>.