TOWER DESIGN AND CONSTRUCTION CHAPTER 2: SITE DESIGN AND DEVELOPMENT<br />

TABLE 2-2 COMPARISON OF TOWER TYPES<br />

Factor Self-Supporting Guyed Monopole<br />

Cost High<br />

More material required<br />

Foundation more expensive<br />

Rigidity High<br />

Self-supporting structure is<br />

typically more stable <strong>and</strong> better<br />

able to resist wind loading.<br />

2.12.1 TOWER DESIGN DRAWINGS<br />

Moderate<br />

More assembly cost required<br />

L<strong>and</strong> costs may be higher<br />

because more area is required<br />

<strong>for</strong> guy wires.<br />

Moderate<br />

Provide resistance to wind<br />

sway, but are susceptible to<br />

torquing, especially when dish<br />

antennas are installed.<br />

L<strong>and</strong> Required Low High - Location of guy anchors<br />

must be far from tower,<br />

requiring more property. May<br />

be unsuitable <strong>for</strong> populated<br />

areas due to l<strong>and</strong> requirements<br />

Height Moderate High - Guyed towers may<br />

exceed 366 m (1200 ft.)<br />

Tower foundation drawings shall show the following in<strong>for</strong>mation at minimum:<br />

Moderate based on loading<br />

Low - wind resistance less than<br />

other types.<br />

Low - Well-suited <strong>for</strong> urban<br />

areas with limited l<strong>and</strong><br />

availability.<br />

Growth Potential Moderate Moderate Low - Monopoles capable of<br />

supporting growth with room to<br />

rent space to other users may<br />

cost significantly more to build.<br />

• Reference to the soil/geotechnical report, including file number, date <strong>and</strong> firm per<strong>for</strong>ming report,<br />

used in calculations <strong>and</strong> design.<br />

• Required concrete compressive strength to be achieved at 28 days<br />

• Grade <strong>and</strong>/or type of rein<strong>for</strong>cing bar<br />

• Concrete coverage requirements<br />

• Whether welding of rebar is permitted<br />

• Whether cold joints are permitted; if so, the joining procedure shall be specified.<br />

• Whether permanent steel casings are permitted <strong>for</strong> caisson installations<br />

• Whether temporary steel casings are or may be required due to the expected soil conditions<br />

• Any recommended concrete installation techniques such as a tremie<br />

• References to all codes (<strong>and</strong> sections of codes) applicable <strong>for</strong> the design<br />

2-18 68P81089E50-B 9/1/05<br />