MINIMUM SITE GROUNDING (EARTHING) REQUIREMENTS CHAPTER 4: EXTERNAL GROUNDING (EARTHING)<br />

FIGURE 4-30 HIGH-COMPRESSION CONNECTORS AND TYPICAL CRIMPING TOOLS<br />

4.7 MINIMUM SITE GROUNDING (EARTHING) REQUIREMENTS<br />

This section provides the minimum grounding (earthing) requirements <strong>for</strong> installing a grounding<br />

electrode system at a <strong>communication</strong>s site <strong>and</strong> <strong>for</strong> bonding site equipment to the grounding electrode<br />

system. Reasonable attempts shall be made to achieve the grounding electrode system resistance design<br />

goal, as defined in “Grounding (Earthing) Electrode System Resistance Requirements” on page 4-46<br />

The requirements <strong>for</strong> installing a typical grounding electrode system are as follows:<br />

• Per<strong>for</strong>m a soil resistivity test at the site as described in Appendix B, “Soil Resistivity<br />

Measurements”<br />

• Calculate the resistance of a single ground rod as described in “Interpreting Test Results” on<br />

page B-10.<br />

• Determine the resistance requirement of the grounding electrode system, based on the site type<br />

(“Light Duty” or “St<strong>and</strong>ard Duty” site). See “Grounding (Earthing) Electrode System Resistance<br />

Requirements” on page 4-46.<br />

4.7.1 TYPE “A” SITE - LIGHT DUTY<br />

MECHANICAL HYDRAULIC BATTERY-POWERED<br />

• Determine if the single ground rod will meet the minimum 25 ohm requirement. If the single<br />

ground rod does not meet the 25 ohm requirement, an additional ground rod, or other grounding<br />

(earthing) electrode, will be required. See “Type “A” Site Grounding (Earthing)” on page 4-48 <strong>for</strong><br />

additional in<strong>for</strong>mation.<br />

• Install the ground rod(s) as described in “Type “A” Site Grounding (Earthing)” on page 4-48 <strong>and</strong><br />

elsewhere throughout this chapter.<br />

NOTE: It is recommended to use two grounding electrodes as the minimum installation, even if 25 ohms is<br />

achieved with a single grounding electrode.<br />

4-44 68P81089E50-B 9/1/05