The following message appears–<br />

F-2<br />

F1: COMSEC<br />

CONNECT DEVICE<br />

S/G M/Z D/D P/N X/E<br />

STEP 5. Connect desired fill device such as, KYK-13, KYX-15, or CYZ-10<br />

(configured for DS-102) to the fill panel connector; the display shows the COMSEC fill<br />

menu when the fill device is turned on.<br />

F1: COMSEC<br />

DS-102<br />

COMSEC Key: _ _<br />

KEY TYPE: VINSN<br />

S/G M/Z D/D P/N X/E<br />

STEP 6. Rotate the selector control knob clockwise, as required, to select COMSEC<br />

key storage position (01 to 19). Next press ENTER (X/E) ↓<br />

STEP 7. Rotate selector control knob to select desired key type (ANDVT, FASCN,<br />

VINSN, or #KG84, where #=1, 2, 3, or 4). (Field defaults to over-the-air rekeying if<br />

position 20 was selected.)<br />

F1: COMSEC<br />

DS-102<br />

COMSEC Key: 01<br />

KEY TYPE: VINSN<br />

S/G M/Z D/D P/N X/E<br />

STEP 8. Set address select (fill) switch on KYK-13 to the desired position.<br />

STEP 9. Press (X/E) ↓ Enter switch on the control indicator and observe that LED<br />

on KYK-13 flashes.<br />

STEP 10. The CI display shows the message Key Filled or Key Fill Failure.<br />

F1: COMSEC<br />

KEY FILLED<br />

COMSEC Key: _ _<br />

KEY TYPE: VINSN<br />

S/G M/Z D/D P/N X/E<br />

STEP 11. If key fill failed message appears, repeat steps 6 through 9 and try to fill<br />

radio again.