(3) DAMA CALL REQUEST<br />

(4) CH PREC = ROUTINE<br />

(5) PORT INTKG OR XMODE appears<br />

(6) Use INTKG, press the down arrow button<br />

(7) CALL PREC: ROUTINE appears (This is the call precedence. Press the<br />

down arrow button.)<br />

(8) CONFERENCE CALL? Yes or No<br />

(9) USER 1<br />

(10) Enter the NET number. Press the down arrow button.<br />

(11) Radio emits RCCOW and displays if it is or is not connected.<br />

(12) If the menu states the RCCOW NACKED, go back to the REQUEST CALL<br />

menu and reinitiate.<br />

(13) After <strong>com</strong>pleting the use of the circuit, press the ESC or the up arrow<br />

button and scroll until the EXIT PRESET is displayed and press number 4.<br />

8. Fill Procedures Using A KYX-15<br />

a. On the KYX-15, select the desired key to be loaded (1 to 16), then set the switch<br />

to the LD position. On the radio, enter and verify on the display the proper storage<br />

location for the variable. Press and release the STO/RCL button on the radio set’s<br />

keypad and the lamp on the KYX-15 flashes when the button is pressed. The message<br />

KG FILL IN PROGRESS is displayed. To verify correct transfer of the variable,<br />

disconnect the KYX-15. If the fill <strong>com</strong>pleted successfully, the message KG FILL<br />

SUCCESSFUL is displayed.<br />

b. Continue with the operating procedures.<br />

9. Key Variable Zeroization<br />

See section 3 above.<br />