uhf tacsat /dama multi-service tactics, techniques ... - UHF-Satcom.com
uhf tacsat /dama multi-service tactics, techniques ... - UHF-Satcom.com
uhf tacsat /dama multi-service tactics, techniques ... - UHF-Satcom.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Message Action<br />
A<br />
Acquisition Failed<br />
C Circuit<br />
Aborted<br />
Denied (Reason)<br />
Mismatch Detected<br />
Preempted<br />
Receive Buffer<br />
Overflow<br />
Set up Queued<br />
(Reason)<br />
Set up Rejected<br />
(Reason)<br />
Table D-4. Messages, 5-kHz DAMA<br />
Terminal is not receiving OW. Check azimuth, power out, and reposition<br />
antenna.<br />
Check previous status messages. If logged out, log in over-the-air. Other<br />
messages include circuit not available (especially DASA) and the reason.<br />
Attempt to re-establish or establish a different type of <strong>service</strong>.<br />
Circuit <strong>service</strong> request is denied for the stated reason. If condition is<br />
correctable, take appropriate action or try again later.<br />
An in<strong>com</strong>ing <strong>service</strong> is established but a mismatch is detected between the<br />
<strong>service</strong> and the current mode settings. Check setting of PT/CT mode and<br />
type of attached data device.<br />
The channel controller preempted the circuit. Wait for it to resume before<br />
transmitting.<br />
Or<br />
Contact was temporarily lost with the controller; wait for it to resume.<br />
Check data device for in<strong>com</strong>plete message or errors in message. If needed,<br />
request source to retransmit message.<br />
Service is queued for the reason supplied.<br />
Local—terminal called is logged in but time-slot is unavailable.<br />
MHOP—terminal called is not logged in with controller. If it is in another<br />
footprint, wait. If it is supposed to be in the current footprint, teardown and<br />
try again later.<br />
Service request is denied for the stated reason. Try again later unless one<br />
of the following reasons is displayed.<br />
Data Rate—Requested a DASA <strong>service</strong> at higher than 2400 bps—no 25-kHz<br />
DASA channel available.<br />
Not Assignable—The LQ from terminal or the destination terminal is poor.<br />
Check LQ in network state menu. If LQ is low, check antenna or raise<br />
power.<br />
Prec. Violation—The precedence entered is not allowed. Check network<br />
state menu for assigned values. Ensure previous messages do not state<br />
logged out. If previous message stated logged out, log in over-the-air and<br />
re-attempt <strong>service</strong> set up at lower precedence.<br />
Service Restrict—Request for a 2400 bps circuit denied due to network<br />
traffic. Reduce data rate or wait until LIO no longer displayed in network<br />
state.<br />
Terminated (Reason) An existing <strong>service</strong> is terminated for the stated reason. Try again later.<br />
COMMAND<br />
Rejected Check parameters and network; try again.<br />
Rejected Port is busy<br />
(Check Current<br />
Mode)<br />
Request is rejected because of an existing active <strong>service</strong>. Ensure terminal is<br />
idle before setting up a <strong>service</strong>.<br />
D-9