Installing Windows 2000 Advanced Server (ES5044R, ES5085R, <strong>and</strong> ES2024R)<br />

Table 3–1. Windows 2000 Advanced Server: ES5044R, ES5085R, <strong>and</strong> ES2024R<br />

<strong>Installation</strong> Checklist<br />

√ Media or Information Required<br />

Your Product Key screen<br />

Registration number ______________________________________<br />

To register Windows 2000 Advanced, you need the key number printed on a label on the back of<br />

the Windows 2000 Advanced CD-ROM jewel case or on the Certificate of Authentication.<br />

Date/Time Properties screen; Time Zone tab screen<br />

Time zone at the site _____________________________<br />

Daylight saving time: If daylight saving time is being used, check the check box provided on the<br />

Time Zone tab screen.<br />

3.1. Determining Whether Software Is Preloaded<br />

Caution<br />

To prevent installation problems or wasted time, determine whether Windows<br />

2000 Advanced has been preloaded. Then follow either the procedure for<br />

preloaded software or the full installation procedure, as appropriate.<br />

To determine whether the Windows 2000 Advanced operating system is preloaded,<br />

perform the steps below.<br />

Notes:<br />

• Before powering on the Intel node, verify that the preloaded RAID disks are installed<br />

in the correct bays as labeled on the disks. See the applicable server system map for<br />

the location <strong>and</strong> layout of the drive bays.<br />

• If you encounter any problems installing the RAD6002-P64 RAID card, refer to the<br />

Unisys Ultra160 RAID Adapter Driver Update Notice (4556 3947).<br />

1. Power the Intel node on <strong>and</strong> allow it to fully boot (takes about 2 minutes).<br />

During the boot, the following message may appear:<br />

DAC1100 found new configuration, it will<br />

reset to update configuration.<br />

DAC1100 reset complete.<br />

That message indicates that the RAID configuration saved in nonvolatile memory by<br />

the RAID controller does not match the current configuration. If no errors occurred<br />

during the reset, proceed to step 11 below. Otherwise, continue with step 2 to correct<br />

the problem.<br />