<strong>Installation</strong> Checklists <strong>and</strong> Tips<br />

Recovering from a PING Test Failure<br />

The most common reason for PING test failure when you test interconnect communications<br />

(Section 14) is lack of an FDDI driver, or an incorrectly installed one, on the Intel<br />

node. Refer to the full operating system software installation procedure, or the Windows<br />

2000, Windows NT, or UnixWare documentation, for steps to correctly install <strong>and</strong><br />

configure the FDDI driver.<br />

2.3.2. Software Tips<br />

These are points to be aware of as you install <strong>and</strong> configure the software. More<br />

information follows in this section.<br />

• Creating emergency recovery diskettes<br />

• Choosing to perform a full installation even when software is preloaded or preinstalled<br />

• Finding the correct license information for SCO UnixWare <strong>and</strong> Enterprise Backup <strong>and</strong><br />

Restore<br />

• Configuring OS 2200 print queues<br />

• Deciding to install Windows NT Server as a primary or backup domain controller<br />

• Changing SPO aliases<br />

• Configuring CMS 1100<br />

• Changing the installation passwords following hardware RFU<br />

• Modifying Windows NT/2000 server network settings after installation<br />

Creating Emergency Recovery Diskettes<br />

You must create an emergency recovery diskette for each Windows 2000 node, each<br />

Windows NT node, each UnixWare node, <strong>and</strong> the SPO server. The procedures for creating<br />

those diskettes are described as part of the procedures for completing installation of<br />

Windows NT (7.1.17), Windows 2000 (7.2.9), <strong>and</strong> UnixWare (8.13).<br />

Performing a Full <strong>Installation</strong> When Software Is Preloaded or Preinstalled<br />

Intel node <strong>and</strong> system console software are preloaded on servers shipped to U.S. sites.<br />

SPO server software, in addition to being preloaded, is preinstalled. Because a full set of<br />

installation media is provided, you may wish to perform the full installation procedure,<br />

even with software preloaded or preinstalled, for the following reasons:<br />

• A problem was encountered while performing the procedure for preloaded or<br />

preinstalled software.<br />

• The site wants to verify that the installation media are good for future use.<br />

• The site wants to train people in installation <strong>and</strong> configuration procedures for a<br />

particular node.<br />

• Some other reason particular to the site or to the system being installed.<br />