The HLC-2 Subsystem Connections<br />

FDDIVI Parameters<br />

MAC Address Vendor # 000000<br />

MAC Address Device # 000000<br />

Number of Devices 2<br />

Device default name HLVI<br />

Configuring the FDDI Interconnect<br />

HLC Devices<br />

Dest. MAC address LSAP/<br />

Name Address Type Vendor # Device # DSAP<br />

HLVI01 1 OUTPUT<br />

HLVI02 2 INPUT<br />

F! = Help, F2 = Choices, F5 = Parameters, Enter = Choose F12 = Done<br />

7. Verify/lock the system <strong>and</strong> partitions, create <strong>and</strong> mark the partitions, <strong>and</strong> send the<br />

ODB to a floppy disk or tape, whichever is preferred.<br />

8. Reboot the SCF in offline mode <strong>and</strong> load the new ODB.<br />

9. Reboot the SCF in online mode, then reboot the 2200 node.<br />

D.1.2. <strong>IX</strong>5000 Series or <strong>IX</strong>4800 Server <strong>Configuration</strong><br />

<strong>IX</strong>5000 Series or <strong>IX</strong>4800 servers need the following hardware components configured in<br />

SCMS system inventory:<br />

• A Power Domain (PWRD) with at least one CSIOP for the required FDDI <strong>and</strong> Ethernet<br />

connections. The CSIOP is identified by Feature Name IOPM-CS under PWRD.<br />

• Connect the FDDI/Ethernet channel adapters to Bus0 of physical IOP0 in Power<br />

Domain 0.<br />

• An FDDI control unit (CS-FDDI) to provide the 2200 connection to the FDDI port in<br />

the Intel node. This control unit must be named FDDIVI for proper OS 2200<br />

identification. With that name, SCMS automatically names the devices as HLVI01<br />

(address=1 type=output) <strong>and</strong> HLVI02 (address=2 type=input). Do not change those<br />

names. No parameter changes are needed in System_Connect/Subsystem.<br />

Add additional control units for additional Intel nodes, as needed, <strong>and</strong> name them as<br />

follows:<br />

− FDDIVJ (device names HLVJ01 <strong>and</strong> HLVJ02 are generated by default) for control<br />

unit 2<br />

− FDDIVK (device names HLVK01 <strong>and</strong> HLVK02 are generated by default) for control<br />

unit 3<br />

− FDDIVL (device names HLVL01 <strong>and</strong> HLVL02 are generated by default) for control<br />

unit 4<br />

7850 5104–009 Version 009B (Web Only) D–5