Customizing the Site<br />

See the documentation for your version of UnixWare for details about installing optional<br />

products.<br />

16.8. Repartitioning the UnixWare Node<br />

Following initial installation, a site may wish to repartition UnixWare. The only method<br />

for doing that, without reinstalling UnixWare, is to create a new partition in the<br />

unallocated free space that was not partitioned during installation. See the <strong>ClearPath</strong> <strong>IX</strong><br />

Operations <strong>Guide</strong> for instructions.<br />

16.9. Configuring Resilient Partitions (2200 Node)<br />

Sites can configure the 2200 node for resilient partitions as shown in Figure 16–1. During<br />

normal operation, the 2200 node connects to the FDDI LAN <strong>and</strong> communicates with the<br />

Intel node through the primary connection. Whenever the primary partition is unavailable,<br />

the resilient connection automatically is made available <strong>and</strong> communication switches from<br />

the primary path to the resilient path.<br />

Take the following steps to configure resilient partitions:<br />

1. Configure the resilient connection in the operations database (ODB) using the Site<br />

<strong>Configuration</strong> Management System (SCMS). This is the responsibility of whoever<br />

generates the ODB. For more information on using SCMS to configure a resilient<br />

connection, see the SCMS Administration <strong>Guide</strong> Volume 1.<br />

2. The resilient connection must be configured in CMS 1100 by site personnel using the<br />

Integration Expert Config Ace tool.<br />

Notes:<br />

• The second 2200 node partition is OS 2200 only. The CMS 1100 configuration for<br />

the second partition cannot contain heterogeneous multiprocessing (HMP)<br />

interconnect components that allow the resilient connection to access the Intel node.<br />

Thus, the two partitions cannot run together as two instances of a <strong>ClearPath</strong> <strong>IX</strong><br />

system.<br />

• When configuring the resilient connection in the ODB using SCMS, the name<br />

FDDIVI must be assigned to the first FDDI control unit <strong>and</strong> FDDIVJ to the second<br />

control unit (see Appendix D). Those names are required by automated<br />

configuration tools.<br />

16–18 Version 009B (Web Only) 7850 5104–009