Installing the Remaining IOE Software<br />

15.2.3. Setting Up Application Group 3<br />

To set up application group 3 so that the UDS tape can be installed, take the following<br />

steps:<br />

1. Application group 3 must be up to start this procedure. Take these steps to check its<br />

state:<br />

a. Check the facility status of the application by entering this comm<strong>and</strong>:<br />

AP 3 FS<br />

The following message should be returned to indicate that IRU short recovery is<br />

pending (“PND”) <strong>and</strong> is in the “INIT” recovery state:<br />

APP 3 RCV 0% IRU:PND REC: INIT<br />

b. If a message indicates that application group 3 is not in the correct recovery state,<br />

enter the following comm<strong>and</strong>s:<br />

AP 3 DN<br />

AP 3 UP INIT<br />

2. Enter the following comm<strong>and</strong> to start the runstream to set up application group 3:<br />

ST AP3SETUP<br />

This runstream does the following to perform an IRU short recovery of application<br />

group 3 (required to set up the application group):<br />

• Creates rollback page file to TIP file 301<br />

• Adds the MCBSETUP3 runstream<br />

• Sets up the IRU history file for application group 3<br />

• Adds the IRU3 runstream to short recover application group 3<br />

Messages appear <strong>and</strong> you are prompted to open an audit trail.<br />

Note: The common bank error messages appear as a result of UDS products not<br />

yet being installed when IRU short recovers application group 3 during the<br />

initial set up. Application group 3 must be up <strong>and</strong> short-recovered when<br />

UDS is initially installed (15.2.4).<br />

SETUP3 START<br />

SETUP3*MSG: CREATE ROLLBACK PAGE FILE FOR APP3<br />

SETUP3*MCB File Setup 8R1A 8R1A (A3)<br />

SETUP3*(940914 1100:56) 1996 May 30 Thu 1103:14<br />

SETUP3*MCB IRU Setup 8R1A 8R1A (A3)<br />

SETUP3*(940914 1101:16) 1996 May 30 Thu 1103:15<br />

SETUP3*MSG: CREATE IRU HISTORY FOR APP 3<br />

SETUP3*MSG: PERFORMING A SHORT RECOVERY OF UDSSRC<br />

Common bank error 9 . -0-><br />

-0-> common bank " UNDETERMINED " with bdi 400665 -0-><br />

-0-> referenced by run-id " SETUP3 " is not installed.<br />

Common bank error 9. bdi 400665 not found -0-><br />

-0-> in omnibus element BANK-BDI$<br />

-0-> in file SYS$*LIB$(1) .<br />

SETUP3*App 3 Init of MCB complete<br />