Verifying the Interconnects <strong>and</strong> Achieving Hardware RFU<br />

Continue with either 14.5.1 or 14.5.2, as determined above.<br />

14.5.1. Starting the PING Run<br />

This subsection describes the quickest way to prepare for hardware verification: the PING<br />

run (PING-RUN). PING-RUN brings up a minimal version of CMS 1100 that supports only<br />

the interconnect communications test (PING test). When the test is complete, the CMS<br />

1100 run started by PING-RUN must be terminated <strong>and</strong> a new CMS 1100 configured <strong>and</strong><br />

started by the site.<br />

Note: The CMS 1100 run started by PING-RUN cannot be used to verify public or SPO<br />

network connections. To create a CMS 1100 that can be left on the system <strong>and</strong><br />

enhanced after hardware verification, follow the procedures in 14.5.2 instead.<br />

To use PING-RUN, take the following steps:<br />

1. Access an OS 2200 console session at either the SPO workstation or at the monitor<br />

concentrator.<br />

2. Enter one of the following console key-ins to start the setup run:<br />

• If this is the only 2200 node, or the first 2200 node in a resilient partition, enter the<br />

following keyin:<br />

ST PING-RUN<br />

A run called CMS starts.<br />

• If this is the second 2200 node in a resilient partition, enter the following keyin:<br />

ST PING-RUN2<br />

A run called CMS2 starts.<br />

Messages similar to the following indicate that CMS 1100 has access to the LAN:<br />

CONFIGURATION ERRORS(0) WARNINGS(0)<br />

LAN FDDIVI FDDI HLC IS USING MICROCODE LEVEL 006.52<br />

LAN FDDIVI MAC ADDRESS = 02E6D3070058<br />

Continue by executing the PING test as described in 14.6.<br />

14.5.2. Bringing Up CMS 1100<br />

This subsection describes basic CMS 1100 configuration considerations <strong>and</strong> considerations<br />

for implementing the <strong>IX</strong> Network Identity Repository (16.2).<br />

To complete the load process <strong>and</strong> verify the system, the site must use CMS 1100. This<br />

subsection gives the procedures for creating a minimum CMS 1100 configuration that is<br />

tailored to the installed external Ethernet LAN. Once the steps in this section are<br />

completed, CMS 1100 is ready to use.<br />

7850 5104–009 Version 009B (Web Only) 14–9