Section 14<br />

Verifying the Interconnects <strong>and</strong><br />

Achieving Hardware RFU<br />

Following installation of OS 2200 software from fast-load tape HMP-OE1, you must verify<br />

that the OS 2200 nodes <strong>and</strong> each Intel node can communicate via the internal interconnect<br />

(14.1).<br />

Table 14–1 lists procedures that require you to have information or installation media<br />

available at the time of installation. Obtain that information or media before beginning.<br />

With this checklist completed <strong>and</strong> all installation software media readily available, the<br />

procedures in this section take 3 hours.<br />

Table 14–1. Checklist for Verifying Interconnects <strong>and</strong> Achieving RFU<br />

√ Media or Information Required<br />

14.1. Verifying Interconnect Communications<br />

Media needed:<br />

Applicable tape containing microcode <strong>and</strong> the PING test for verifying communications as follows:<br />

• Model <strong>IX</strong>4400<br />

CEC500 tape (minimum level of 1R8 is required, except when the 2200 node is configured<br />

for resilient partitions, then a minimum level of 1R11 is required to execute the PING test for<br />

the second 2200 node)<br />

Host LAN Controller-2 (HLC-2) microcode on cartridge tape. Found in the HLC2-FMK package<br />

that comes with the HLC-2.<br />

• Model <strong>IX</strong>5000 Series or <strong>IX</strong>4800 server<br />

CC6000 tape or CC3000 tape. CC6000 supersedes CC3000 for all configurations at<br />

Plateau 2.0. At Plateau 2.0 a minimum CC6000 level of 2R1 is required. Below Plateau 2.0,<br />

a minimum CC3000 level of 1R1 is required, except when the 2200 node is configured for<br />

resilient partitions, then a minimum level of 1R2 is required to execute the PING test for the<br />

second 2200 node.<br />

Channel adapter microcode tape, called FDDI/ETHERNET CA-MCODE<br />

The Diagnostic Software Peripheral Equipment Routines (DSPER) also should be installed following<br />

installation of the CEC tape.<br />

continued<br />

7850 5104–009 Version 009B (Web Only) 14–1