Installing the Basic OS 2200 IOE<br />

5. Set jump keys for library load (jump key 4) <strong>and</strong> initialization (jump key 13) as follows:<br />

sj 4,13<br />

Whenever jump key 13 is set, a prompt appears with a field for specifying the<br />

reinitialize option.<br />

6. In the field that appears, set the reinitialize option by typing the following entry <strong>and</strong><br />

pressing Enter twice.<br />

destroyfiles<br />

7. Load the tape HMP-BOOT in the tape drive specified in step 2.<br />

8. Start the partition by entering the following SCF comm<strong>and</strong>:<br />

sp<br />

The Start Partition comm<strong>and</strong> initializes the partition <strong>and</strong> performs an initial program<br />

load of the partition.<br />

9. Press the F4 key to change to the System Operations session. The following message<br />

is displayed:<br />

n MODIFY CONFIG, THEN ANSWER: DONE<br />

10. Before continuing the boot process, determine the current state of peripheral devices<br />

by entering appropriate facility status (fs) keyins. For example, check the status of all<br />

mass storage devices with the following keyin:<br />

fs,ms<br />

You can use this keyin to display only disks that are up:<br />

fs,adisk<br />

11. Use the UP or DN keyin to set devices to the state you want for the partition.<br />

12. When done, end modification of the configuration by entering the following:<br />

n done<br />

where n is the number of the MODIFY CONFIG message requiring a response.<br />

In response to that message, the following message appears:<br />

n ARE YOU SURE YOU WANT JK 13 SET? ANSWER Y OR N<br />

13. Enter Y to confirm that you want to perform an initial boot:<br />

n Y<br />

A messages appears indicating the number of fixed mass storage disks that are up:<br />

n F<strong>IX</strong>ED MS DEVICES= m - CONTINUE? YN<br />

14. Answer yes (Y).<br />

n Y<br />

A message solicits down keyins. You must bring down disks that should not be up.<br />

n ENTER LOCAL DOWN PACK KEYINS - ANS GO<br />

15. Enter keyins to down devices as needed. (If no device must be downed, continue with<br />

the next step.) For example,<br />

7850 5104–009 Version 009B (Web Only) 13–5