Configuring Intel Nodes for Monitoring by SPO<br />

12.9. Running the Console Output Redirection<br />

Script<br />

Cautions<br />

1. For each UnixWare node, create an emergency recovery diskette that you can<br />

use to reboot the node if the console redirection procedure should fail (8.13).<br />

2. SPO daemons must be running on the SPO server in order to redirect console<br />

output as described in this subsection. See 10.16 if they are not running.<br />

3. Before running the URM installation script, verify in the TopCluster window that<br />

the SPO server, the UnixWare node, <strong>and</strong> the system console icons are green.<br />

Green icons indicate that the SPO server has a normal connection to those<br />

components. If the icons have not turned green within about 30 seconds of<br />

starting normal operations, ensure that all SPO daemons are running by<br />

stopping <strong>and</strong> restarting them as described in 10.16.<br />

The script described in this section can h<strong>and</strong>le both manual installation of the URM agent<br />

<strong>and</strong> console output redirection. However, only the redirection feature of this script is<br />

actually used. (See step 7 below.)<br />

To use this procedure, SPO Console sites must have Console 4.3 or higher installed in the<br />

default location.<br />

If the TopCluster window did not appear when normal SPO Basic Edition operations were<br />

started, click Displays on the main menu bar, then click Cluster in the drop-down menu<br />

that appears.<br />

After starting SPO Basic Edition operations (12.7), run the script to install URM agent files<br />

on each UnixWare node <strong>and</strong> to redirect console output from the node to the SPO server so<br />

that the node can be monitored by SPO Basic Edition.<br />

The procedure, which you must do for each UnixWare node, is as follows:<br />

1. In the TopCluster diagram of SPO Console, click the icon of the UnixWare node<br />

(CP_UN<strong>IX</strong>x) to open a console session. You must open a SPO session to monitor the<br />

node because the node will not boot if a process is not monitoring the serial port.<br />

2. At the system console of the UnixWare node, log on to the node as the root user (userid<br />

root) if you are not already logged on, as follows:<br />

a. Double-click Applications, then Terminal.<br />

The dollar sign ($) prompt appears.<br />

b. Type the su comm<strong>and</strong>, then press Enter.<br />

You are prompted to enter a password.<br />

12–12 Version 009B (Web Only) 7850 5104–009