24.12.2012 Views

ClearPath IX Systems Installation and Configuration Guide

ClearPath IX Systems Installation and Configuration Guide

ClearPath IX Systems Installation and Configuration Guide

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Installing UnixWare 7<br />

39. Press any key to reboot the UnixWare 7 system.<br />

After the system reboots, a Mouse Selection screen appears.<br />

40. Configure the mouse as follows:<br />

a. Tab to select the PS/2-compatible mouse, then press F10.<br />

b. The default number of buttons is two. Press F10.<br />

c. Press Enter to start the mouse test.<br />

d. Move the mouse.<br />

e. Press a mouse button to end the test.<br />

When you are finished testing the mouse, the following message appears:<br />

To continue installing the system, insert CD-ROM #2 <strong>and</strong> press .<br />

41. Insert the CD-ROM <strong>and</strong> press F10.<br />

42. When the window “Select products to install” appears, press Enter.<br />

43. At Enhanced Event Logging System <strong>Installation</strong>, Enter Default Database Location<br />

window, tab to apply <strong>and</strong> press Enter.<br />

44. When the window “The following products were successfully installed:” appears,<br />

press F10.<br />

45. Another message appears asking for CD-ROM #3. Press .<br />

The system automatically boots into multi-user mode.<br />

<strong>Installation</strong> of the UnixWare 7 operating system is now complete.<br />

Continue by installing the UnixWare <strong>and</strong> Open Server Development Kit (8.4.2).<br />

8.4.2. Installing the UnixWare <strong>and</strong> Open Server Development Kit<br />

(UDK)<br />

Note: This procedure is required for each <strong>ClearPath</strong> <strong>IX</strong> node running the UnixWare 7<br />

operating system.<br />

To install the UnixWare <strong>and</strong> OpenServer Development Kit (UDK):<br />

1. Log on as the root user (user-id root) (8.12.1).<br />

2. Insert the UnixWare 7 UnixWare <strong>and</strong> OpenServer Development Kit (UDK) CD-ROM<br />

into the CD-ROM drive.<br />

3. From the comm<strong>and</strong> line at the root directory, type the following comm<strong>and</strong>, <strong>and</strong> press<br />

Enter:<br />

pkgadd -d cdrom1<br />

4. Press Enter to continue.<br />

You receive a message asking you not to remove the CD-ROM from the drive. Then<br />

you are prompted to select the package you want to add (there is only one).<br />

7850 5104–009 Version 009B (Web Only) 8–21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!