Completing Windows <strong>Installation</strong><br />

help menu item from the Global Array Manager Client to learn how to operate it. If you<br />

have an RAD5003-P64 RAID card in your server <strong>and</strong> discover that the Array Manager does<br />

not find the card, you will need to update the driver using the following procedure:<br />

1. Launch the System applet from Start > Settings > Control Panel > System.<br />

2. Click the Hardware tab to get to the Device Manager start button. Click the button.<br />

3. In the device manager, open the “SCSI <strong>and</strong> RAID controllers” device tree <strong>and</strong> doubleclick<br />

the DAC1164P card.<br />

4. Click the driver tab, then click the Update Driver button.<br />

5. The Upgrade Device Driver Wizard starts. Click Next.<br />

6. Click the “Display a list…” option button, then click Next.<br />

7. Click “Have disk” <strong>and</strong> insert the Unisys Supplementatl Drivers CD into the server’s<br />

drive.<br />

8. Click Browse <strong>and</strong> select the CD drive (D:) from the drop-down box.<br />

9. Double-click the win2000 folder.<br />

10. Double-click the raid folder.<br />

11. Double-click the Dac960nt folder.<br />

12. Double-click the Dac1164p folder.<br />

13. Click to select the Dac1164p file icon, then click Open.<br />

14. Click OK.<br />

15. Click to select the RAID controller item, then click Next.<br />

16. Click Next, then click Finish.<br />

Continue by installing ControlIT (7.2.4).<br />

7.2.4. Installing <strong>and</strong> Configuring ControlIT<br />

ControlIT software, a product of Computer Associates, enables full monitoring <strong>and</strong> control<br />

of Windows NT nodes from the Single Point Operations (SPO) workstation. To implement<br />

that monitoring <strong>and</strong> control, ControlIT must be installed <strong>and</strong> configured on each Windows<br />

node as described in this subsection.<br />

The ControlIT software is also installed on the SPO workstation (see Section 11).<br />

Note: The ControlIT CD-ROM is included in the SPO software package. Use the same<br />

CD-ROM to install ControlIT on both the SPO workstation <strong>and</strong> the Windows NT<br />

node.<br />

The procedure for installing ControlIT is as follows:<br />

1. If you are not currently logged on, power on or restart the Windows 2000 node <strong>and</strong> log<br />

on as the administrator.<br />

2. Insert the ControlIT CD-ROM into the drive unit.<br />

7–22 Version 009B (Web Only) 7850 5104–009