Installing Windows NT Server 4.0 (DR/2) 6.1. Determining Whether Software Is Preloaded Caution To prevent installation problems, or wasted time, determine whether Windows NT has been preloaded. Then follow either the procedure for preloaded software or the full installation procedure, as appropriate. To determine whether the Windows NT operating system is preloaded, 1. Power on the Intel node and allow it to fully boot (takes about 2 minutes). 2. If the Windows NT Software License Agreement screen appears, the operating system is preloaded. If Windows NT is preloaded, perform the steps described in 6.2. Then complete the installation as described in Section 7. If Windows NT is not preloaded, 1. Configure the RAID controller (6.3). 2. Install the Windows NT operating system (6.4). 3. Log on to Windows NT (6.5). 4. Complete the installation (Section 7). 6.2. Steps to Take If Windows NT Is Preloaded You must take the steps below to initially configure Windows NT when it is preloaded. Notes: • Before powering on the Intel node, verify that the preloaded RAID disks are installed into the correct bays as labeled on the disks. See the DR/2 system map for the location and layout of the drive bays. • If you decide to perform a full installation even though the system is preloaded, do not format the RAID disk. Instead, use the DAC BIOS utility to initialize the RAID volume before you reload the operating system. Formatting the disk makes the drive unrecognizable to the software. 1. Power the Intel node on and allow it to fully boot (takes about 2 minutes). Watch the messages on the screen for the ALT-R prompt. 2. Press Alt-R to start the Mylex RAID EzAssist utility. An EzAssist Menu for configuring RAID logical arrays appears as follows: ----EzAssist Menu---- Configure RAID Drive 6–4 Version 009B (Web Only) 7850 5104–009

Installing Windows NT Server 4.0 (DR/2) View or Modify Controller Configuration Perform Administration on... Rescan for New Devices Advanced Options 3. Use the arrow keys to select the Configure RAID Drive option, then press Enter. A Configuration Method menu appears: ------Configuration Method----- Automatic Assisted Custom Note: Unless noted otherwise, use the arrow keys to select menu options throughout the rest of this procedure. 4. If there are no disks to configure, return to the EzAssist menu (step 7) and select Advanced Options; then select “clear configuration.” You will then be able to configure the RAID drive. 5. Select Automatic, then press Enter. The RAID Configuration Summary window appears: RAID Configuration Summary Logical Drive 0 Fault Tolerance: Yes Spare: No Optimization: Performance Logical Drive Count: 1 Total Capacity: 17.0 GB Chan: 10 Vendor Model Version Capacity (GB) Status 1:00 UNISYS ....... 17.0 Online 1:01 UNISYS ....... 17.0 Online A message window appears: Writing RAID Configuration Please wait... A final window appears: Congratulations! Configuration Status Logical Drive 0 RAID configuration is successful. You may utilize this drive immediately. [Reboot] Main Menu 6. Press Ctrl-Alt-Del to reboot. A Software License Agreement screen appears. 7. Have the client, or a representative of the client, accept the license agreement as follows: 7850 5104–009 Version 009B (Web Only) 6–5

Installing Windows NT Server 4.0 (DR/2)<br />

6.1. Determining Whether Software Is Preloaded<br />

Caution<br />

To prevent installation problems, or wasted time, determine whether Windows NT<br />

has been preloaded. Then follow either the procedure for preloaded software or<br />

the full installation procedure, as appropriate.<br />

To determine whether the Windows NT operating system is preloaded,<br />

1. Power on the Intel node <strong>and</strong> allow it to fully boot (takes about 2 minutes).<br />

2. If the Windows NT Software License Agreement screen appears, the operating system<br />

is preloaded.<br />

If Windows NT is preloaded, perform the steps described in 6.2. Then complete the<br />

installation as described in Section 7.<br />

If Windows NT is not preloaded,<br />

1. Configure the RAID controller (6.3).<br />

2. Install the Windows NT operating system (6.4).<br />

3. Log on to Windows NT (6.5).<br />

4. Complete the installation (Section 7).<br />

6.2. Steps to Take If Windows NT Is Preloaded<br />

You must take the steps below to initially configure Windows NT when it is preloaded.<br />

Notes:<br />

• Before powering on the Intel node, verify that the preloaded RAID disks are installed<br />

into the correct bays as labeled on the disks. See the DR/2 system map for the<br />

location <strong>and</strong> layout of the drive bays.<br />

• If you decide to perform a full installation even though the system is preloaded, do<br />

not format the RAID disk. Instead, use the DAC BIOS utility to initialize the RAID<br />

volume before you reload the operating system. Formatting the disk makes the drive<br />

unrecognizable to the software.<br />

1. Power the Intel node on <strong>and</strong> allow it to fully boot (takes about 2 minutes).<br />

Watch the messages on the screen for the ALT-R prompt.<br />

2. Press Alt-R to start the Mylex RAID EzAssist utility.<br />

An EzAssist Menu for configuring RAID logical arrays appears as follows:<br />

----EzAssist Menu----<br />

Configure RAID Drive<br />

6–4 Version 009B (Web Only) 7850 5104–009